Altronix MAXIMAL33F | Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, Dual 12/24VDC P/S @ 6A each, FAI, LinQ2 Ready, 115VAC, BC800 Enclosure
Altronix MAXIMAL33F | Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, Dual 12/24VDC P/S @ 6A each, FAI, LinQ2 Ready, 115VAC, BC800 Enclosure

Altronix MAXIMAL33F | Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, Dual 12/24VDC P/S @ 6A each, FAI, LinQ2 Ready, 115VAC, BC800 Enclosure

Part Number: 552886
0 Review(s)
Write a Review
Availability:
$967.60
Retail Price:$1,064.36
Your Savings:$96.76(9%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Maximal33F Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Enclosure

  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 19"W x 26"H x 6.25"D (483 mm W x 660.4 mm H x 159 mm D).
  • 1/2" and 3/4" combination knockouts.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

  • 120VAC 60Hz, 7.0A input
  • Power supply input options:
  • a) Two (2) common power input for either ACM8 and lock power (factory installed).
  • b) Two (2) isolated power inputs (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A total.
  • Sixteen (16) Access Control System trigger inputs
  • Input options:
  • a) Sixteen (16) normally open (NO) inputs.
  • b) Sixteen (16) open collector inputs.
  • c) Any combination of the above.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

  • 12VDC and/or 24VDC outputs
  • Maximum output current Options:
  • a) 12VDC @ 5.3A plus 12VDC @ 5.3A.
  • b) 12VDC @ 5.3A plus 24VDC @ 5.6A.
  • c) 24VDC @ 5.6A plus 24VDC @ 5.6A.
  • Non power-limited outputs.
  • Sixteen (16) independently controlled outputs
  • Output options:
  • a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
  • b) Sixteen (16) form "C" 5A rated relay outputs.
  • c) Any combination of the above.
  • Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5A).
  • Filtered and electronically regulated outputs (built-in power supply).
  • Thermal and short circuit protection with auto reset.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Fuse Ratings

  • Power Supply input fuse rated @ 5A/250V.
  • ACM8 boards main fuse is rated at 10A. Fused outputs are rated @ 3.5A each.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Supervision

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 2 hours.
  • Battery fail and presence supervision (form "C" contacts).
  • Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.



https://www.alldataresource.com/assets/images_commscope/packaging_weights.jpg

Weights (approximate)

Product Weight32.6 Lbs. (14.8 kg).
Shipping Weight39.6 Lbs. (18 kg).



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Agency Listings

UL Listed For: Access Control System Units (UL294)https://iq.ulprospector.com/en/profile?e=1521
cUL Listed For: CSA Standard C22.2 No.205-M1983, Signal Equipmenthttps://iq.ulprospector.com/en/profile?e=152141



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Altronix MAXIMAL33F Data SheetClick to View
Altronix MAXIMAL33F Data SheetClick to View
Altronix MAXIMAL33F Fichas TecnicasClick to View
Altronix MAXIMAL33F Installation Instructions prior to Jul. 6, 2015Click to View
Altronix MAXIMAL33F Altronix_MAXIMAL33F_Power_Controller_Installation_Instructions_prior_to_Jan._10,_2015.pdfClick to View
Altronix MAXIMAL33FInstallation InstructionsClick to View
Altronix MAXIMAL33F Guia de InstalacionClick to View
Altronix MAXIMAL33F Revit FileClick to View
Altronix MAXIMAL33F Lifetime WarrantyClick to View

Related Items

Recently Viewed Items