Tripp-Lite SU20K3/3 | SmartOnline 3-Phase 120/208V 20kVA 16kW Double-Conversion UPS, Extended Run, 2 internal batteries, Network Card Options, Tower, DB9 Serial, Hardwire
Tripp-Lite SU20K3/3 | SmartOnline 3-Phase 120/208V 20kVA 16kW Double-Conversion UPS, Extended Run, 2 internal batteries, Network Card Options, Tower, DB9 Serial, Hardwire

Tripp-Lite SU20K3/3 | SmartOnline 3-Phase 120/208V 20kVA 16kW Double-Conversion UPS, Extended Run, 2 internal batteries, Network Card Options, Tower, DB9 Serial, Hardwire

Tripp-Lite 20Kva/16Kw, 208V In/Out, 3Ph, 4W, Ups Wi
Part Number: 325339
0 Review(s)
Write a Review
Availability:
$12,029.05
Retail Price:$12,527.13
Your Savings:$498.08(4%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Tripp Lite's SU20K3/3 20kVA SmartOnline 3-Phase Intelligent, True On-Line UPS System has been redesigned to save valuable space and simplify runtime scalability. Power and battery components are combined into a single, small-footprint module (the smallest in its class). A robust internal battery runtime capability can be easily extended by installing additional optional internal battery packs through the convenient front panel access door. The SU20K3/3 provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA/16,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. IGBT inverter technology produces output power with <3% THD (total harmonic distortion), allowing connected equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands. Extremely efficient operation saves money by lowering electricity consumption. Hardwire input and output connections. SU20K3/3 features 120/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 96-144/166-250V AC. Frequency is 50 or 60 Hz (auto-selectable). SU20K3/3 includes internal power and battery components in a single small-footprint tower module. Battery support can be extended with additional internal battery packs. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power when the UPS requires maintenance. Three built-in communication ports (RS-232, contact closure and AS-400) work with PowerAlert Software, available via free download, to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories. An accessory slot accepts an optional internal network management card. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions. A start-up service program is recommended to enhance the reliability of the installation.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • Saves valuable space: power and battery components combined into a single small-footprint module
  • Simplifies runtime scalability: convenient front panel battery access for expandable runtime with additional internal battery packs
  • True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
  • 20,000VA / 16,000 watt power capacity with 3-phase, hardwire 120/208V AC input/output connections
  • Features a wide input voltage correction range: 96 - 144 / 166 - 250V AC
  • Included internal batteries provide 13 minutes runtime at half load (8,000 watts) and 5 minutes runtime at full load (16,000 watts)
  • 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands
  • Extend runtime by installing optional internal battery packs (model # SURBC2030) through the front panel access door. SU20K3/3 includes 2 internal battery packs and accepts 2 additional internal battery packs. A standalone battery module compartment with a 4 battery pack capacity and daisy-chain capability (model # SUBF2030) is available to further extend runtime.
  • 3 communication ports (RS-232, contact closure and AS-400)
  • Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
  • Manual bypass switch as well as an automatic bypass function ensures 100% availability of connected equipment by safely passing through AC power when the UPS system requires maintenance
  • Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval
  • Emergency Power Off button turns UPS output OFF and disables Bypass output
  • Start-up service program is recommended to enhance the reliability of the installation
  • Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities
  • Combination LED/LCD display



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332136664
UPS TypeOn-Line



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load)60A
Nominal Input Voltage(s) Supported120/208V 3-PH Wye
Nominal Input Voltage Description3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS Input Connection TypeHardwire
Input Phase3-Phase



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA)20000
Output kVA Capacity (kVA)20
Output Watt Capacity (Watts)16000
Output kW Capacity (kW)16
Power Factor0.8
Crest Factor3:1
Frequency Compatibility50 / 60 Hz
Output Voltage Regulation (Line Mode)+/- 2%
Output Voltage Regulation (Battery Mode)+/- 2%
Output AC Waveform (AC Mode)Sine wave



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Full Load Runtime (min.)5 min. (16kw)
Half Load Runtime (min.)13 min. (8kw)
Expandable Battery RuntimeSupports extended runtime with 2 internal and multiple optional external battery packs
Expandable RuntimeYes
Expandable Runtime DescriptionIncludes a battery housing with space for 2 internal  SURBC2030  battery packs for extended runtime. Additional runtime capacity is available by adding SUBF2030 and additional  SURBC2030  batteries - see runtime chart for specific recommendations



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage CorrectionMaintains continuous operation without using battery power during overvoltages to 144 / 250 (3-Phase, 4-Wire, wye), reducing output within 2% of nominal



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Front Panel LCD DisplaySELECTABLE LCD DISPLAY: indicates a wide range of UPS operational and fault/warning conditions including operational mode, alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage and more (see manual)
SwitchesON button turns UPS's inverter ON. OFF button turns UPS's inverter OFF. Select Button browses through items displayed on LCD screen. Enter button selects items displayed on LCD screen. Select and Enter buttons used simultaneously mute UPS alarms. Battery Start Switch cold starts the inverter. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass switch bypasses the UPS's inverter during maintenance.
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating2032
AC Suppression Response TimeInstantaneous



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Management CardsSNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD
Network Monitoring Port DescriptionRS232; contact closure and AS400 monitoring ports are supported by 3 separate DB9 ports
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications CableDB9 cabling included
Communications InterfaceDB9 Serial; Contact closure; Slot for SNMP/Web interface



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

SU20K3/3 runtime chartClick to View
Unpacking InstructionsClick to View
Owner's Manual for SmartOnline 3-Phase 20kVA & 30kVA UPSClick to View
Owner's Manual for Battery Module Compartment Model: SUBF2030 (English)Click to View
3-Phase UPS Systems Visio StencilClick to View
3-Phase UPS Systems Visio Stencil PreviewClick to View
Integrated Solutions Brochure (English)Click to View
EC DeclarationClick to View
UPS SizingClick to View
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server ApplicationsClick to View
UPS Systems Buying GuideClick to View
Custom Products from Tripp Lite Are One Call AwayClick to View
Economy Mode ExplainedClick to View

Recently Viewed Items