ABB GAF185-10-11-72 - CONTACTOR - DC.CTR, DC1-250A, 20-60VDC, 1/1
ABB GAF185-10-11-72 - CONTACTOR - DC.CTR, DC1-250A, 20-60VDC, 1/1

ABB GAF185-10-11-72 - CONTACTOR - DC.CTR, DC1-250A, 20-60VDC, 1/1

Part Number: 618645
0 Review(s)
Write a Review
Availability:
$1,156.30
Retail Price:$1,216.22
Your Savings:$59.92(5%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

ABB GAF185-10-11-72 - CONTACTOR - DC.CTR, DC1-250A, 20-60VDC, 1/1



https://www.alldataresource.com/assets/images_commscope/information.jpg

General Information

Extended Product Type:GAF185-10-11-72
Product ID:1SFL497025R7211
EAN:7320500383766
Catalog Description:GAF185-10-11 20-60V DC Contactor
Long Description:A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 20-60 V, DC



https://www.alldataresource.com/assets/images_commscope/ordering_tree.jpg

Ordering

Minimum Order Quantity:1 piece
Customs Tariff Number:85364900



https://www.alldataresource.com/assets/images_commscope/dimensions.jpg

Dimensions

Product Net Width:111.5 mm
Product Net Depth / Length:160 mm
Product Net Height:196 mm
Product Net Weight:3 kg



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Technical

Number of Main Contacts NO:1
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:1
Number of Auxiliary Contacts NC:1
Rated Operational Voltage:Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 275 A
Rated Operational Current DC-1 (Ie):(1000 V) 3 Poles in Series, 40 °C 275 A, (1000 V) 3 Poles in Series, 55 °C 250 A, (1000 V) 3 Poles in Series, 70 °C 180 A, (220 V) 3 Poles in Series, 40 °C 275 A, (220 V) 3 Poles in Series, 55 °C 250 A, (220 V) 3 Poles in Series, 70 °C 180 A, (400 V) 3 Poles in Series, 40 °C 275 A, (400 V) 3 Poles in Series, 55 °C 250 A, (400 V) 3 Poles in Series, 70 °C 180 A, (600 V) 3 Poles in Series, 40 °C 275 A, (600 V) 3 Poles in Series, 55 °C 250 A, (600 V) 3 Poles in Series, 70 °C 180 A
Rated Insulation Voltage (Ui):acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
Mechanical Durability:5 million
Maximum Mechanical Switching Frequency:300 cycles per hour
Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C)
Rated Control Circuit Voltage (Uc):DC Operation 20 ... 60 V
Coil Consumption:Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A, Holding at Max. Rated Control Circuit Voltage DC 2 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 500 W
Connecting Capacity Main Circuit:Bar 24 mm², Rigid Al-Cable 25 ... 150 mm², Rigid Cu-Cable 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:Main Circuit: Bars



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Technical UL/CSA

Maximum Operating Voltage UL/CSA:Main Circuit 600 V
General Use Rating UL/CSA:(1000 V DC) 250 A, (440 V DC) 250 A, (600 V DC) 250 A



https://www.alldataresource.com/assets/images_commscope/environmental_test_specifications.jpg

Environmental

Ambient Air Temperature:Operation -40 ... +80 °C, Storage -40 ... +70 °C
Maximum Operating Altitude Permissible:3000 m
Resistance to Shock acc. to IEC 60068-2-27:Shock Direction: A 5 K40, Shock Direction: B1 5 K40, Shock Direction: B2 5 K40, Shock Direction: C1 5 K40, Shock Direction: C2 5 K40
RoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019



https://www.alldataresource.com/assets/images_commscope/information.jpg

Container Information

Package Level 1 Units:box 1 piece
Package Level 1 Width:178 mm
Package Level 1 Depth / Length:232 mm
Package Level 1 Height:167 mm
Package Level 1 Gross Weight:3.6 kg
Package Level 1 EAN:7320500383766



https://www.alldataresource.com/assets/images_commscope/product_classification.jpg

Classifications

Object Classification Code:Q
ETIM 4:EC002552 - Power contactor, DC switching
ETIM 5:EC002552 - Power contactor, DC switching
ETIM 6:EC002552 - Power contactor, DC switching
ETIM 7:EC002552 - Power contactor, DC switching
UNSPSC:39121529
IDEA Granular Category Code (IGCC):4763 >> Power contactor, DC switching



https://www.alldataresource.com/assets/images_commscope/information.jpg

Popular Downloads

Instructions and Manuals:Click to Download
Dimension Diagram:Click to Download



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Certificates and Declarations (Document Number)

CCC Certificate:Click to Download
CQC Certificate:Click to Download
cUL Certificate:Click to Download
Declaration of Conformity - CCC:Click to Download
Declaration of Conformity - CE:Click to Download
EAC Certificate:Click to Download
Environmental Information:Click to Download
Instructions and Manuals:Click to Download
RoHS Information:Click to Download
UL Listing Card:Click to Download



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

ABB GAF185-10-11-72 Overview - PDF Format

Download Product Details in PDF FormatClick to Download

Recently Viewed Items