General Information

Extended Product Type:MO325-6.3
Product ID:1SAM160000R1009
EAN:4013614302053
Catalog Description:MO325-6.3 Manual Motor Starter Magnetic Only
Long Description:The MO325-6.3 manual motor starter magnetic only is a 54 mm width device with a rated operational current of Ie = 6.3 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter magnetic only offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC. Further features are the build-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.



https://www.alldataresource.com/assets/images_commscope/ordering_tree.jpg

Ordering

Minimum Order Quantity:1 piece
Customs Tariff Number:85362010
Replacement Product ID (NEW):1SAM360000R1009



https://www.alldataresource.com/assets/images_commscope/dimensions.jpg

Dimensions

Product Net Width:54 mm
Product Net Height:87.5 mm
Product Net Depth / Length:75.5 mm
Product Net Weight:0.34 kg



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 70 kA, (500 V AC) 40 kA, (690 V AC) 7 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 70 kA, (500 V AC) 40 kA, (690 V AC) 7 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):67.7 A
Setting Range:None
Rated Operational Power AC-3 (Pe):(400 V) Three Phase 2.2 kW
Rated Operational Voltage:Main Circuit 690 V AC, Main Circuit 440 V DC
Rated Operational Current (Ie):6.3 A
Rated Operational Current AC-3 (Ie):6.3 A
Rated Frequency (f):Main Circuit 50 Hz, Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
Rated Insulation Voltage (Ui):690 V
Power Loss:at Rated Operating Conditions per Pole 2 W
Number of Poles:3
Conventional Free-air Thermal Current (Ith):Main Circuit 6.3 A
Degree of Protection:Housing IP20, Main Circuit Terminals IP20
Pollution Degree:3
Electrical Durability:50000 cycle
Mechanical Durability:100000 cycle
Terminal Type:Screw Terminals
Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 0.75 ... 4 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm², Flexible 1/2x 1 ... 6 mm², Rigid 1/2x 1 ... 6 mm²
Tightening Torque:Main Circuit 1.4 N·m
Wire Stripping Length:Main Circuit 10 mm
Recommended Screw Driver:M3.5Pozidriv 2
Mounting Position:Position 1 to 6
Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Actuator Type:Rotary Handle
Contact Position Indication:ON / OFF
Standards:CSA 22.2 No. 14IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 508
Remarks:For overload protection of the motors, an appropriate thermal or electronic overload relays must be used



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Technical UL/CSA

Maximum Operating Voltage UL/CSA:Main Circuit 600 V AC
Ampere Rating UL/CSA:6.3 A
Horsepower Rating UL/CSA:(220 ... 240 V AC) Three Phase 1.5 Hp, (440 ... 480 V AC) Three Phase 3 Hp, (550 ... 600 V AC) Three Phase 5 Hp
Connecting Capacity Main Circuit UL/CSA:Flexible 1/2x 14-8 AWG, Stranded 1/2x 14-8 AWG
Tightening Torque UL/CSA:Main Circuit 14 in·lb



https://www.alldataresource.com/assets/images_commscope/environmental_test_specifications.jpg

Environmental

Ambient Air Temperature:Around the Enclosure 0 ... +40 °C, Operation -25 ... +50 °C, Storage -50 ... +80 °C
Ambient Air Temperature Compensation:No
Maximum Operating Altitude Permissible:2000 m
Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 15g
Resistance to Vibrations acc. to IEC 60068-2-6:5g / 10 ... 150 Hz
RoHS Status:Following EU Directive 2011/65/EU



https://www.alldataresource.com/assets/images_commscope/information.jpg

Container Information

Package Level 1 Units:box 1 piece
Package Level 1 Width:92 mm
Package Level 1 Depth / Length:58 mm
Package Level 1 Height:78 mm
Package Level 1 Gross Weight:0.37 kg
Package Level 1 EAN:4013614302053
Package Level 2 Units:carton 24 piece
Package Level 2 Width:280 mm
Package Level 2 Depth / Length:395 mm
Package Level 2 Height:210 mm
Package Level 2 Gross Weight:8.9 kg
Package Level 2 EAN:4013614495014



https://www.alldataresource.com/assets/images_commscope/product_classification.jpg

Classifications

Object Classification Code:F
ETIM 4:EC000074 - Motor protective circuit-breaker
ETIM 5:EC000074 - Motor protective circuit-breaker
ETIM 6:EC000074 - Motor protection circuit-breaker
ETIM 7:EC000074 - Motor protection circuit-breaker
eClass:V11.0 : 27370401
UNSPSC:39121521
IDEA Granular Category Code (IGCC):4845 >> 3 Pole Motor Circuit Protector Circuit Breakers



https://www.alldataresource.com/assets/images_commscope/information.jpg

Popular Downloads

Data Sheet, Technical Information:Click to Download
Instructions and Manuals:Click to Download



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

ABB MO325-6.3 Overview - PDF Format

Download Product Details in PDF FormatClick to Download

Related Items

Recently Viewed Items