Altronix AL400ULACMCB | Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 4A, FAI, 115VAC, BC400 Enclosure
Altronix AL400ULACMCB | Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 4A, FAI, 115VAC, BC400 Enclosure

Altronix AL400ULACMCB | Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 4A, FAI, 115VAC, BC400 Enclosure

Part Number: 355092
0 Review(s)
Write a Review
Availability:
$296.40
Retail Price:$326.04
Your Savings:$29.64(9%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Altronix AL400ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both FailSafe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Enclosure

  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/12AH Batteries.
  • Dimensions 12"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D).
  • 1.125" and 1.375" combination knockouts.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

  • Input 115VAC 60Hz rated @ 3.5A
  • Power supply input options:
  • a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
  • b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
  • Eight (8) Access Control System trigger inputs
  • Input options:
  • a) Eight (8) normally open (NO) inputs.
  • b) Eight (8) open collector inputs.
  • c) Any combination of the above.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

  • 12VDC or 24VDC outputs.
  • 12VDC @ 4A supply current or 24VDC @ 3A supply current.
  • Class 2 Rated PTC protected power limited auto-resettable outputs.
  • Eight (8) independently controlled outputs
  • Output options:
  • Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • Eight (8) auxiliary power outputs (unswitched)



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output ratings

  • PTCs are rated @ 2.5A.
  • Filtered and electronically regulated outputs (built-in power supply).
  • ACM8 board main fuse is rated at 10A.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Supervision

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery and battery presence supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/packaging_weights.jpg

Weights (approximate)

Product Weight10.7 Lbs. (4.85 kg).
Shipping Weight12 Lbs. (5.44 kg).



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Agency Listings

UL Listed For: Access Control System Units (UL294)https://iq.ulprospector.com/en/profile?e=1521
cUL Listed For: CSA Standard C22.2 No.205-M1983, Signal Equipmenthttps://iq.ulprospector.com/en/profile?e=152141



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Altronix AL400ULACMCB Data SheetClick to View
Altronix AL400ULACMCB Data SheetClick to View
Altronix AL400ULACMCB Fichas TecnicasClick to View
Altronix AL400ULACMCB Installation InstructionsClick to View
Altronix AL400ULACMCB Altronix_AL400ULACMCB_Power_Controller_Installation_Instructions_prior_to_Jul._6,_2015.pdfClick to View
Altronix AL400ULACMCBInstallation Instructions prior to Feb. 27, 2015Click to View
Altronix AL400ULACMCB Guia de InstalacionClick to View
Altronix AL400ULACMCB CAD DrawingClick to View
Altronix AL400ULACMCB Revit FileClick to View
Altronix AL400ULACMCB Lifetime WarrantyClick to View

Recently Viewed Items