Altronix AL600ACM220 | Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC @ 6A, FAI, 220VAC, BC400 Enclosure
Altronix AL600ACM220 | Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC @ 6A, FAI, 220VAC, BC400 Enclosure

Altronix AL600ACM220 | Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC @ 6A, FAI, 220VAC, BC400 Enclosure

Part Number: 742767
0 Review(s)
Write a Review
Availability:
$333.74
Retail Price:$361.68
Your Savings:$27.94(8%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

AL600ACM220 converts a nominal 220VAC 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Enclosure

  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/12AH Batteries.
  • Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D).
  • 1.125" and 1.375" combination knockouts.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
  • Short circuit and thermal overload protection.
  • AC fail supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

  • Nominal 220VAC (range 198VAC - 256VAC) 50/60Hz rated @ 1.2A
  • Power supply input options:
  • a) One (1) common power input for ACM8 and lock power (factory installed).
  • b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
  • Eight (8) Access Control System trigger inputs
  • Input options:
  • a) Eight (8) normally open (NO) inputs.
  • b) Eight (8) open collector inputs.
  • c) Any combination of the above.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

  • 12VDC or 24VDC @ 6A supply current.
  • Eight (8) independently controlled outputs
  • Output options:
  • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • b) Eight (8) form "C" 5A rated relay outputs.
  • c) Any combination of the above.
  • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings:
  • Fuses are rated @ 3.5A.
  • Filtered and electronically regulated outputs (built-in power supply).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Visual Indicators

  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
  • AC input and DC output LED indicators.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery Backup

  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Battery fail and battery presence supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/packaging_weights.jpg

Weights (approximate)

Product Weight18.05 Lbs. (8.19 kg).
Shipping Weight19.35 Lbs. (8.78 kg).



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Altronix AL600ACM220 Data SheetClick to View
Altronix AL600ACM220 Data SheetClick to View
Altronix AL600ACM220 Installation InstructionsClick to View
Altronix AL600ACM220 Installation Instructions prior to Jul. 6, 2015Click to View
Altronix AL600ACM220 Revit FileClick to View
Altronix AL600ACM220 Lifetime WarrantyClick to View

Related Items