Altronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Enclosure

  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/12AH Batteries.
  • Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D).
  • 1.125" and 1.375" combination knockouts.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
  • Short circuit and thermal overload protection.
  • AC fail supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

  • Input 115VAC 60Hz rated @ 3.5A
  • Power supply input options:
  • a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
  • b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
  • Eight (8) Access Control System trigger inputs
  • Input options:
  • a) Eight (8) normally open (NO) inputs.
  • b) Eight (8) open collector inputs.
  • c) Any combination of the above.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

  • 12VDC or 24VDC @ 6A supply current.
  • Eight (8) independently controlled outputs
  • Output options:
  • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • b) Eight (8) form "C" 5A rated relay outputs
  • c) Any combination of the above.
  • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings:
  • Fuses are rated @ 3.5A.
  • Filtered and electronically regulated outputs (built-in power supply).
  • ACM8 board main fuse is rated at 10A.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Supervision

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery and battery presence supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Visual Indicators

  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
  • AC input and DC output LED indicators.



https://www.alldataresource.com/assets/images_commscope/packaging_weights.jpg

Weights (approximate)

Product Weight10.3 Lbs. (4.67 kg).
Shipping Weight11.6 Lbs. (5.26 kg).



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Agency Listings

UL Listed For: Access Control System Units (UL294)https://iq.ulprospector.com/en/profile?e=1521
cUL Listed For: CSA Standard C22.2 No.205-M1983, Signal Equipmenthttps://iq.ulprospector.com/en/profile?e=152141



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Altronix AL600ULACM Data SheetClick to View
Altronix AL600ULACM Data SheetClick to View
Altronix AL600ULACM Fichas TecnicasClick to View
Altronix AL600ULACM Installation InstructionsClick to View
Altronix AL600ULACM Altronix_AL600ULACM_Power_Controller_Installation_Instructions_prior_to_Jul._6,_2015.pdfClick to View
Altronix AL600ULACMInstallation Instructions prior to Feb. 27, 2015Click to View
Altronix AL600ULACM Guia de InstalacionClick to View
Altronix AL600ULACM CAD DrawingClick to View
Altronix AL600ULACM Revit FileClick to View
Altronix AL600ULACM Lifetime WarrantyClick to View

Recently Viewed Items