Altronix AL600ULACMCBJ | Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 6A, FAI, 115VAC, BC600G Enclosure
Altronix AL600ULACMCBJ | Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 6A, FAI, 115VAC, BC600G Enclosure

Altronix AL600ULACMCBJ | Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 6A, FAI, 115VAC, BC600G Enclosure

Part Number: 552848
0 Review(s)
Write a Review
Availability:
$376.80
Retail Price:$414.48
Your Savings:$37.68(9%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Altronix AL600ULACMCBJ converts a 115VAC 60Hz input Into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock/accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Enclosure

  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/18AH Batteries.
  • Dimensions 14.5"W x 18"H x 4.62"D (368 mm W x 457 mm H x 118 mm D).
  • 1/2" and 3/4" combination knockouts.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.
  • AC fail supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

  • Input 115VAC 60Hz rated @ 3.5A
  • Power supply input options:
  • a) One (1) common power input for ACM8CB and lock power (factory installed).
  • b) Two (2) isolated power inputs - One (1) to power the ACM8CB and one (1) for lock accessory power (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A total).
  • Eight (8) Access Control System trigger inputs
  • Input options:
  • a) Eight (8) normally open (NO) inputs.
  • b) Eight (8) open collector inputs.
  • c) Any combination of the above.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

  • 12VDC or 24VDC @ 6A supply current.
  • ACM8CB board main fuse is rated at 10A.
  • Eight (8) independently controlled outputs
  • Output options:
  • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • b) Eight (8) form "C" 5A rated relay outputs
  • c) Any combination of the above.
  • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings:
  • PTCs are rated @ 2.5A.
  • Filtered and electronically regulated outputs (built-in power supply).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Supervision

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery and battery presence supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Visual Indicators

  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
  • AC input and DC output LED indicators.



https://www.alldataresource.com/assets/images_commscope/packaging_weights.jpg

Weights (approximate)

Product Weight14.85 Lbs. (6.74 kg).
Shipping Weight17.1 Lbs. (7.76 kg).



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Agency Listings

UL Listed For: Access Control System Units (UL294)https://iq.ulprospector.com/en/profile?e=1521
cUL Listed For: CSA Standard C22.2 No.205-M1983, Signal Equipmenthttps://iq.ulprospector.com/en/profile?e=152141



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Altronix AL600ULACMCBJ Data SheetClick to View
Altronix AL600ULACMCBJ Data SheetClick to View
Altronix AL600ULACMCBJ Fichas TecnicasClick to View
Altronix AL600ULACMCBJ Installation InstructionsClick to View
Altronix AL600ULACMCBJ Altronix_AL600ULACMCBJ_Power_Controller_Installation_Instructions_prior_to_Jul._20,_2015.pdfClick to View
Altronix AL600ULACMCBJInstallation Instructions prior to Feb. 27, 2015Click to View
Altronix AL600ULACMCBJ Guia de InstalacionClick to View
Altronix AL600ULACMCBJ CAD DrawingClick to View
Altronix AL600ULACMCBJ Revit FileClick to View
Altronix AL600ULACMCBJ Lifetime WarrantyClick to View

Recently Viewed Items