Altronix EFLOW104NKA8 | Dual Output Power Supply/Charger, 8 Fuse Protected Auxiliary Class 2 Power-limited Outputs

Altronix eFlow104NKA8 sub-assembly kit converts a 120VAC 60Hz input into eight (8) fuse protected outputs. Outputs are individually selectable, providing 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power) for access control panels, door locks, and ancillary devices. Power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink, normally open (NO), normally closed (NC) dry trigger input, or wet output from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. eFlow104NKA8 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8 modules. This feature allows you to distribute the power over more outputs for larger systems.




https://www.alldataresource.com/assets/images_commscope/information.jpg

Altronix - EFLOW104NKA8 - Overview

  • eFlow104NB Power Supply/Charger
  • Input
  • Voltage: 120VAC, 60Hz, 4.5A max.
  • Input Fuse: 6.3A / 250V.
  • Outputs
  • Voltage: 24VDC @ 10A.
  • Auxiliary: 1A (unswitched).
  • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Backup (not included)
  • Type: Sealed lead acid or gel type.
  • Fuse Rating: 10A @ 32VDC.
  • Failover: Upon AC loss, instantaneous.
  • Fire Alarm Disconnect
  • Supervised: Latching or non-latching.
  • EOL: 10K Resistor.
  • Supervision
  • AC Failure: Form "C" contacts.
  • Battery: Form "C" contacts.
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
  • AC Input: 120VAC is present.
  • DC Output: Powered.
  • Battery: Discharged or not connected.
  • VR6 Voltage Regulator
  • Input
  • Voltage: 24VDC from eFlow104NB.
  • Output
  • Voltage: 12VDC.
  • Current: 6A continuous.
  • Other: Surge suppression.
  • Indicators LED
  • Input: 24VDC is present.
  • Output: Powered.
  • ACMS8 Dual Input Access Power Controller
  • Input
  • Voltage: 24VDC from eFlow104NB and 12VDC or 5VDC from VR6.
  • Input Fuse: 15A / 32V.
  • Outputs
  • Voltage: 12 or 24VDC individually selectable.
  • Eight (8) selectable 12VDC or 24VDC independently controlled outputs or eight (8) indepently controlled Form "C" relay outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs.
  • b) Form "C" Relays. 28VAC or VDC @ 2.5A Rated.
  • c) Auxiliary power outputs (unswitched).
  • d) Any combination of the above.
  • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
  • Individual outputs may be set to OFF position for servicing.
  • Output Fuses: 3A / 32VDC.
  • Indicators (LED)
  • Red LEDs: Outputs are triggered (relays energized).
  • Blue LED: FACP disconnect is triggered.
  • Out1 - Out8: Bi-colored LEDs indicate 12 or 24VDC.
  • Environmental
  • Temperature
  • Operating: 0° C to 49° C (32° F to 120° F).
  • Storage: - 20° C to 70° C ( - 4° F to 158° F).
  • Relative Humidity
  • Relative Humidity 85% +/- 5%.
  • BTU/Hr (approx.):
  • 123 BTU/Hr.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Altronix - EFLOW104NKA8 - Features

  • Wall mount enclosure for indoor use.
  • 1.125" and 1.375" combination knockouts.
  • Unit provides 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power)
  • Additional aux. Class 2 power-limited output rated @ 1A
  • Short circuit and overvoltage protection
  • Fire alarm disconnect
  • Bi-colored LEDs provide visual verification of voltage on each output



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Altronix - EFLOW104NKA8 - Specifications

UNSPSC Code24102001.0
Agency ListingsCE Compliant
Dimensions (approximate)12"W x 15.5"H x 4.5"D (304.8 mm W x 393.7 mm H x 114.3 mm D).



https://www.alldataresource.com/assets/images_commscope/dimensions.jpg

Altronix - EFLOW104NKA8 - Weights (approximate)

Product Weight9.4 Lbs. (4.26 kg).
Shipping Weight10.5 Lbs. (4.76 kg).



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Altronix - EFLOW104NKA8 - Documents and Downloads

Altronix EFLOW104NKA8 Data SheetClick to View
Altronix EFLOW104NKA8 Installation InstructionsClick to View

Recently Viewed Items