Altronix EFLOW104NKA8QM | Networkable Dual Output Power Supply/Charger, 8 Fuse Protected Auxiliary Class 2 Power-limited Outputs
Altronix EFLOW104NKA8QM | Networkable Dual Output Power Supply/Charger, 8 Fuse Protected Auxiliary Class 2 Power-limited Outputs

Altronix EFLOW104NKA8QM | Networkable Dual Output Power Supply/Charger, 8 Fuse Protected Auxiliary Class 2 Power-limited Outputs

Part Number: 10169337
0 Review(s)
Write a Review
Availability:
$749.97
Retail Price:$824.97
Your Savings:$75.00(9%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Altronix EFLOW104NKA8QM | Networkable Dual Output Power Supply/Charger, 8 Fuse Protected Auxiliary Class 2 Power-limited Outputs

Altronix eFlow104NKA8QM sub-assembly kit converts a 120VAC 60Hz input into eight (8) fuse protected outputs. Outputs are individually selectable, providing 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power) for access control panels, door locks, and ancillary devices. Power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink, normally open (NO), normally closed (NC) dry trigger input, or wet output from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. eFlow104NKA8QM will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple LINQ8ACM modules. This feature allows you to distribute the power over more outputs for larger systems. Built-in LINQTM Network Power Management facilitates monitoring, reporting and control of power/diagnostics.




https://www.alldataresource.com/assets/images_commscope/information.jpg

Altronix - EFLOW104NKA8QM - Overview

  • eFlow104NB Power Supply/Charger
  • Input
  • Voltage: 120VAC, 60Hz, 4.5A max.
  • Input Fuse: 6.3A / 250V.
  • Outputs
  • Voltage: 24VDC @ 10A.
  • Auxiliary: 1A (unswitched).
  • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Backup (not included)
  • Type: Sealed lead acid or gel type.
  • Fuse Rating: 10A @ 32VDC.
  • Failover: Upon AC loss, instantaneous.
  • Fire Alarm Disconnect
  • Supervised: Latching or non-latching.
  • EOL: 10K Resistor.
  • Supervision
  • AC Failure: Form "C" contacts.
  • Battery: Form "C" contacts.
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
  • AC Input: 120VAC is present.
  • DC Output: Powered.
  • Battery: Discharged or not connected.
  • VR6 Voltage Regulator
  • Input
  • Voltage: 24VDC from eFlow104NB.
  • Output
  • Voltage: 12VDC.
  • Current: 6A continuous.
  • Other: Surge suppression.
  • Indicators LED
  • Input: 24VDC is present.
  • Output: Powered.
  • LINQ8ACM Network Access Power Controller
  • Input
  • Voltage: 24VDC from eFlow104NB and 12VDC or 5VDC from VR6.
  • Input Fuses: 15A / 32V.
  • Outputs
  • Fuse protected outputs rated @ 2.5A per output, non power-limited. Total output 20A max.
  • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
  • Individual outputs may be set to OFF position for servicing.
  • Output Fuses: 3A / 32VDC.
  • Programming Features
  • Eight (8) Programmable Outputs
  • Eight (8) Programmable Trigger Inputs
  • - Normally open (NO).
  • - Normally colsed (NC).
  • - Wet Input (5VDC - 24VDC) with 10k resistor.
  • Other Programmable Trigger Inputs
  • - Monitor power supply(ies) input for voltage and currect limits (high/low).
  • Fire Alarm Disconnect
  • Supervised: Inactive, latching or non-latching, individually selectable for any or all of the eight (8) outputs.
  • EOL: 10K Resistor.
  • LED Indicators
  • Green AC LED: indicates AC trouble condition.
  • Green BAT LED: indicates battery trouble condition.
  • Green FACP LED: indicates FACP disconnect is triggered.
  • Flashing Blue Heartbeat LED: indicates network connection.
  • Individual OUT1 - OUT8 Red LEDs: indicate outputs are triggered.
  • Out1 - Out8: Bi-colored LEDs indicate 12 or 24VDC.
  • Environmental
  • Temperature
  • Operating: 0° C to 49° C (32° F to 120° F).
  • Storage: - 20° C to 70° C ( - 4° F to 158° F).
  • Relative Humidity
  • Relative Humidity 85% +/- 5%.
  • BTU/Hr (approx.):
  • 123 BTU/Hr.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Altronix - EFLOW104NKA8QM - Features

  • Wall mount enclosure for indoor use.
  • 1.125" and 1.375" combination knockouts.
  • Unit provides 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power)
  • Additional aux. Class 2 power-limited output rated @ 1A
  • Short circuit and overvoltage protection
  • Fire alarm disconnect
  • Bi-colored LEDs provide visual verification of voltage on each output



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Altronix - EFLOW104NKA8QM - Specifications

UNSPSC Code24102001.0
Agency ListingsCE Compliant
Dimensions (approximate)12"W x 15.5"H x 4.5"D (304.8 mm W x 393.7 mm H x 114.3 mm D).



https://www.alldataresource.com/assets/images_commscope/dimensions.jpg

Altronix - EFLOW104NKA8QM - Weights (approximate)

Product Weight9.4 Lbs. (4.26 kg).
Shipping Weight10.5 Lbs. (4.76 kg).



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Altronix - EFLOW104NKA8QM - Documents and Downloads

Altronix EFLOW104NKA8QM Data SheetClick to View
Altronix EFLOW104NKA8QM Installation InstructionsClick to View