Altronix MAXIMAL3D | Access Power Controller w/ Power Supply/Charger, 16 PTC Class 2 Relay Outputs, 12/24VDC @ 6A, 115VAC, BC800 Enclosure
Altronix MAXIMAL3D | Access Power Controller w/ Power Supply/Charger, 16 PTC Class 2 Relay Outputs, 12/24VDC @ 6A, 115VAC, BC800 Enclosure

Altronix MAXIMAL3D | Access Power Controller w/ Power Supply/Charger, 16 PTC Class 2 Relay Outputs, 12/24VDC @ 6A, 115VAC, BC800 Enclosure

Part Number: 552891
0 Review(s)
Write a Review
Availability:
$803.58
Retail Price:$883.94
Your Savings:$80.36(9%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Enclosure

  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/12AH Batteries.
  • Dimensions 19"W x 26"H x 6.25"D (483 mm W x 660.4 mm H x 159 mm D).
  • 1/2" and 3/4" combination knockouts.



https://www.alldataresource.com/assets/images_commscope/features.jpg

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

  • 115VAC 60Hz, 3.5A input
  • Power supply input options:
  • a) Two (2) common power input for either ACM8 and lock power (factory installed).
  • b) Two (2) isolated power inputs (external power supply is required), (current is determined by the power supply connected, not to exceed a maximum of 10A total).
  • Sixteen (16) Access Control System trigger inputs
  • Input options:
  • a) Sixteen (16) normally open (NO) inputs.
  • b) Sixteen (16) open collector inputs.
  • c) Any combination of the above.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

  • 12VDC or 24VDC outputs
  • Maximum output current:
  • 12VDC @ 5A or 24VDC @ 5.4A.
  • Class 2 Rated power limited outputs (auto-resettable).
  • Sixteen (16) independently controlled outputs can be Fail-Safe and/or Fail-Secure power outputs.
  • Sixteen (16) auxiliary power outputs (unswitched), (outputs are rated 2A).
  • Filtered and electronically regulated outputs (built-in power supply).
  • Thermal and short circuit protection with auto reset.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Fuse Ratings

  • Power Supply input fuse rated @ 3.5A/250V.
  • ACM8CB boards main fuse is rated at 10A. Output PTCs are rated @ 2.5A.



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Supervision

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery and battery presence supervision (form "C" contact).



https://www.alldataresource.com/assets/images_commscope/packaging_weights.jpg

Weights (approximate)

Product Weight30.8 Lbs. (14 kg).
Shipping Weight37.8 Lbs. (17.2 kg).



https://www.alldataresource.com/assets/images_commscope/regulatorycompliance.jpg

Agency Listings

UL Listed For: Access Control System Units (UL294)https://iq.ulprospector.com/en/profile?e=1521
cUL Listed For: CSA Standard C22.2 No.205-M1983, Signal Equipmenthttps://iq.ulprospector.com/en/profile?e=152141



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Altronix MAXIMAL3D Data SheetClick to View
Altronix MAXIMAL3D Data SheetClick to View
Altronix MAXIMAL3D Fichas TecnicasClick to View
Altronix MAXIMAL3D Installation InstructionsClick to View
Altronix MAXIMAL3D Altronix_MAXIMAL3D_Power_Controller_Installation_Instructions_prior_to_Jan._10,_2015.pdfClick to View
Altronix MAXIMAL3DInstallation Instructions prior to Jul. 20, 2015Click to View
Altronix MAXIMAL3D Guia de InstalacionClick to View
Altronix MAXIMAL3D CAD DrawingClick to View
Altronix MAXIMAL3D Revit FileClick to View
Altronix MAXIMAL3D Lifetime WarrantyClick to View