Honeywell Fire Systems MS-9600LS Intelligent Addressable Fire Alarm System
Honeywell Fire Systems MS-9600LS Intelligent Addressable Fire Alarm System

Honeywell Fire Systems MS-9600LS Intelligent Addressable Fire Alarm System

Fire-Lite Alarms, Inc. 636-Point Addressable Fire Alarm Ctrl Pa
Part Number: FIL-MS9600LS
0 Review(s)
Write a Review
Availability:
$1,413.66
Retail Price:$1,472.20
Your Savings:$58.54(4%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

FireLite’s MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels) with an extensive list of powerful features. The combination of FireLite’s newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLSE FACP, offer the latest in fire protection technology. LiteSpeed is a patented technology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the system polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification circuits in under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. The FLPS-7 power supply is a separate board while all other electronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabinet. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chassis with the electronics can be quickly installed with two bolts. The MS-9600UDLS(E) includes a factory-installed DACT-UD2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Station via internet (optional IPDACT installed) or the public switched telephone network. Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download software and remote power expansion.

Features
  • Easy mount chassis
  • 7 amp switching power supply
  • Large enclosure allows 18 amp-hour batteries
  • DACT-UD2 plug-in communicator standard with MS-9600UDLS/E
  • Optional IPDACT Internet Protocol Digital Alarm Communicator/Transmitter
  • Four Style Y (Class B) or two Style Z (Class A) NAC circuits
  • Selectable strobe synchronization per NAC for
  • System Sensor, Wheelock, and Gentex devices
  • Automated control of ACC-25/50(ZS/T) audio speaker circuits
  • ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used
  • Optional 4XTMF module (conventional reverse polarity/city box transmitter)

    Specs
  • Manufacturer Honeywell Fire Systems Us / Fire-Lite
  • Condition New
  • Primary input power: 120 VAC, 50/60 Hz, 3.0 A. 240 VAC, 50 Hz, 1.5 A
  • Battery: 27.6 VDC @ 1.0 A (max)
  • Maximum battery charger capacity: 26 AH
  • Minimum battery: 12 AH
  • MS-9600LS cabinet holds maximum of two 18 AH batteries
  • Communication Loop: 24 VDC nominal, supervised and power-limited
  • Notification Appliance Circuits: terminal block provides connections for four Style Y (Class B) or two Style Z (Class A) NACs
  • Maximum signaling current per circuit: 3.0 A
  • End-of-Line Resistor: 4.7 K ohms, ½ watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Supervised and power-limited
  • Two Programmable Form-C Relays and One Fixed Trouble Form-C Relay: Contact rating: 2.0 A @ 30 VDC (resistive) 0.5 A @ 30 VAC (resistive)
  • Four-wire Resettable Special Application Power (24 VDC nominal): Up to 1.5 A for powering four-wire smoke detectors.
  • Power-limited, nonsupervised