Tripp-Lite 2000 Watts 230V 50/60 Hz
Part Number: 444272
0 Review(s)
Write a Review
Availability:
$432.41
Retail Price:$468.60
Your Savings:$36.19(8%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

The LR2000 2000W 230V Power Conditioner adjusts under- and overvoltages to provide safe, computer-grade AC power. Built-in automatic voltage regulation (AVR) offers three levels of voltage stabilization that correct undervoltages as low as 168V and overvoltages as high as 278V back to regulated 240V, 220V or 208V nominal power. Providing optimum voltage conditions not only extends the life of your equipment, but also keeps your equipment working through brownouts and prolonged overvoltage conditions.

A network-grade 1360-joule surge suppression rating exceeds the IEEE-587 standard for surge suppression (both categories A and B) and prevents even the strongest spikes from inflicting damage, data loss or corruption and audio/video performance problems on your connected equipment. EMI/RFI noise filtering protects your AC line from disruptive electromagnetic and radio interference.

Just connect the detachable 6.5-ft. (1.98 m) NEMA 6-15P to C13 power cord to an AC power source, and plug up to six devices into the outlets. Two NEMA 5-15R, two NEMA 6-15R and two C13 outlets accommodate a wide range of connected components. An included UNIPLUGINT universal adapter allows most worldwide plug configurations to connect to the LR2000's C13 outlets. You can monitor incoming voltage status using the five diagnostic LEDs on the front panel. The compact LR2000 fits comfortably into your computer or home theater setup.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • Protects Valuable Electronics
  • Rated at 230V/2000W/8.7A
  • Ideal for computers, routers, modems, printers, home theater components and point-of-sale equipment
  • Connect up to 6 electronic devices to the rear outlets: 2 NEMA 5-15R, 2 NEMA 6-15R and 2 C13
  • Includes detachable 6.5 ft. (1.98 m) NEMA 6-15P to C13 power cord
  • Included UNIPLUGINT universal adapter fits into C13 outlet and accepts most worldwide plug configurations
  • Compact unit (7 in./17.8 cm high) fits comfortably into your computer or home theater setup
  • Automatic Voltage Regulation (AVR)
  • Maintains regulated, selectable 240/220/208V nominal output
  • Monitors incoming AC power and keeps equipment working through brownouts and prolonged overvoltage conditions
  • Corrects undervoltages as low as 168V and overvoltages up to 278V
  • Boosts the following input voltages by 18.2%:
  • At or below 203V (240V AC setting)
  • At or below 188V (220V AC setting)
  • At or below 178V (208V AC setting)
  • Boosts the following input voltages by 9%:
  • 204-223V (240V AC setting)
  • 189-204V (220V AC setting)
  • 179-193V (208V AC setting)
  • Reduces the following input voltages by 9.8%:
  • Over 255V (240V AC setting)
  • Over 234V (220V AC setting)
  • Over 221V (208V AC setting)
  • AC Line Surge Suppression
  • 1360 joules of network-grade surge suppression protects against potentially harmful power surges and spikes
  • Includes full normal (H-N) and common (N-G/H-G) line surge suppression
  • EMI/RFI Line Noise Filtering
  • Removes electromagnetic and radio frequency interference that can disrupt or damage your equipment's performance
  • Built-In Diagnostics
  • Front-panel LEDs indicate incoming voltage status
  • Rear on/off switch provides one-touch power control over all components



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332040282



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Maximum Input Amps / Watts10A
Input Cord Length (ft.)6.5



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output (Watts)2000
Nominal Output Voltage(s) Supported230V



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation DescriptionMaintains usable 208/220/240V nominal output to sensitive electronics during severe brownouts and overvoltages.
Overvoltage CorrectionInput voltages above 255V (240V AC setting); 234V (220V AC setting); 221V (208V AC setting) are reduce by 9.8%
Brownout CorrectionInput voltages below 204–223V (240V AC setting); 189–204V (220V AC setting); or 179–193V (208V AC setting) are boosted by 9%
Severe Brownout CorrectionInput voltages below 203V (240V AC setting); 188V (220V AC setting); or 178V (208V AC setting) are boosted by 18.2%



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Front Panel LEDs5 LEDs show incoming voltage status (Very Low / Low / Normal / High / Very High)



https://www.alldataresource.com/assets/images_tripplite/physical_specifications.jpg

Physical

Form Factors SupportedSmall tower placement supported
Material of ConstructionPolycarbonate
Shipping Dimensions (hwd / in.)8.00 x 8.50 x 10.20
Shipping Weight (lbs.)13.30
Unit Dimensions (hwd / in.)7 x 6 x 7
Unit Weight (lbs.)12



https://www.alldataresource.com/assets/images_tripplite/warranty.jpg

Warranty

Product Warranty Period (International)2-year limited warranty