Tripp-Lite PDU3XEVSR6L2230 | 17.3kW 3-Phase Switched PDU - LX Platform, 12 C13 & 12 C19 200-240V Outlets, L22-30P 380-415V Input, Outlet Monitoring, TAA
Tripp-Lite PDU3XEVSR6L2230 | 17.3kW 3-Phase Switched PDU - LX Platform, 12 C13 & 12 C19 200-240V Outlets, L22-30P 380-415V Input, Outlet Monitoring, TAA

Tripp-Lite PDU3XEVSR6L2230 | 17.3kW 3-Phase Switched PDU - LX Platform, 12 C13 & 12 C19 200-240V Outlets, L22-30P 380-415V Input, Outlet Monitoring, TAA

Part Number: 9810611
0 Review(s)
Write a Review
Availability:
$1,888.29
Retail Price:$2,026.05
Your Savings:$137.76(7%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

3-phase switched PDU distributes, monitors and manages power in a medium/large data center or network installation.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • 3-Phase PDU Distributes, Monitors and Manages Network-Grade Power
  • Recommended for data centers, server rooms and high-density network closets, this switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU's total cost of ownership.
  • 24 Outlets Dispense AC Power to Connected Equipment
  • During normal operation, 24 individually controllable outlets—12 C13 and 12 C19—in six separately breakered load banks distribute AC power to rack equipment. Each 220-240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
  • Pre-Installed WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control
  • The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.
  • Color Touchscreen LCD Offers Important Data at a Glance
  • An easy-to-navigate color touchscreen LCD reports network data, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.
  • Easy to Install Vertically in an EIA-Standard 19 in. Rack
  • The 70-inch 0U PDU mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A 6-ft. (1.83 m) cord with NEMA L22-30P 380-415V 3-phase input connects the switched PDU to a compatible AC power source, generator or protected UPS.
  • TAA-Compliant for GSA Schedule Purchases
  • The PDU3XEVSR6L2230 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
  • 2-Year Warranty
  • The PDU3XEVSR6L2230 is backed by a 2-year warranty, ensuring reliability and performance.



https://www.alldataresource.com/assets/images_tripplite/applications.jpg

Applications

  • Power mission-critical rack equipment in a data center, computer room or high-density network closet
  • Monitor power loads from various computers, switches, servers and other networking equipment
  • Maintain a computer network in a government, commercial or industrial facility
  • Manage multiple rack devices by rebooting or shutting down individual outlets as needed



https://www.alldataresource.com/assets/images_commscope/features.jpg

Highlights

  • 12 C13 and 12 C19 220-240V outlets distribute AC power to connected equipment
  • Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
  • Remote power monitoring and control reduces on-site visits and maintenance costs
  • 6-ft. (1.83 m) cord with NEMA L22-30P 380-415V 3-phase input connects to compatible AC source
  • Color touchscreen LCD provides current levels, environmental data and network info



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332206862.0
PDU TypeSwitched



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

PDU Input Voltage380-415V
Recommended Electrical ServiceThree-phase 30A 380-415V service
Maximum Input Amps24
PDU Plug TypeNEMA L22-30P
Input Phase3-Phase
Input Cord Details10GA (ST)



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Capacity Details17.3kW (415/240V), 16.6kW (400/230V), 15.8kW (380/220V) total capacity; 24A max per output phase (L1, L2, L3); 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility50 / 60 Hz
Output Receptacles(12) C13; (12) C19
Output Nominal Voltage220-240V
Overload Protection6 20A circuit breakers, one per output load bank
Customized Load Management ReceptaclesEach outlet is individually controllable via remote interface



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Reported Load SegmentsSupports monitoring of current per input phase (L1, L2, L3), output current per load bank (Banks 1-6) and per output receptacle (1-24); Outlets are color-coded and labeled for phase and load bank identification; L1-N powers black outlets (Banks 1&4); L2-N powers dark-gray outlets (Banks 2&5); L3-N powers light-gray outlets (Banks 3&6)
Front Panel LCD DisplayTouchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules; Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Front Panel LEDsOne LED for each output receptacle offers power availability information: GREEN (Power ON), YELLOW (Warning condition), RED (Critical condition). Network Activity (Green): Flashes for network activity. Link/Network Speed (Yellow): On steady for any speed.
SwitchesLX Platform Interface: Recessed reset switch for interface reboot and factory reset
Current Measurement Accuracy (Amps)+/-1%



https://www.alldataresource.com/assets/images_tripplite/physical_specifications.jpg

Physical

Form Factors SupportedVertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
Material of ConstructionMetal



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Environmental

Operating Temperature Range0C ~ 50C (32F ~ 122F)
Storage Temperature Range-30°C to +60°C (-22°F to +140°F)
Relative Humidity5 to 95% non-condensing



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

PowerAlert SoftwareLX Platform Interface: PowerAlert Device Manager15 (PADM15)
Communications CableUSB B-to-USB A Configuration/Console Access cable
Network Monitoring PortRJ45 Network port, RJ45 Config/Console Access port; 2x USB A ports supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. USB B port (Configuration & Console Access)
SNMP CompatibilitySNMP V1, V2c, V3
Network Speed10/100 Mbps; 1Gbps
Communications InterfacePre-installed network card; RS-232; USB



https://www.alldataresource.com/assets/images_commscope/features.jpg

Special Features

High Availability PDU FeaturesAuto Probe Monitoring and Reboot (included)



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Standards & Compliance

CertificationsTested to UL60950-1: 2007 R12.11, IEC 60950-1: 2005+A1:2009 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011 (Canada), NOM (Mexico), FCC Class A (Emissions), RoHS (Hazardous Substances), TAA Compliant



https://www.alldataresource.com/assets/images_tripplite/warranty.jpg

Warranty

Product Warranty Period (Worldwide)2-year limited warranty



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

Owner's Manual for 3-Phase Switched 0U Power Distribution Units (Multi-language)Click to View
User's Guide for WEBCARDLX PowerAlert Device Manager (English)Click to View
PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface User's Guide (English)Click to View
PowerAlert Device Manager (PADM) 20.0.0 Command Line InterfaceClick to View
PowerAlert Device Manager (PADM) 20.0.0Click to View
Auto Probe Solution for Monitoring and Rebooting Locked-Up Devices (English)Click to View
SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)Click to View