Brand: Tripp-Lite
|
SKU:
509433
Tripp-Lite SMART1500RM2UN | SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets
Regular price
$2,196.53
Unit price
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Brand: Tripp-Lite
|
SKU:
509433
Regular price
$2,196.53
Unit price
Description
Description
Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise. Pre-installed
WEBCARDLX network interface permits remote UPS management 24/7.
Features
- Protects Mission-Critical Rack-Mounted Equipment
- Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
- Audible alarm signals loss of utility power, overload, low battery and fault conditions
- 8 NEMA 5-15R outlets (4 are switchable)
- 10-ft. (3.05 m) power cord with 120V NEMA 5-15P input
- 0.9 power factor rating
- 570-joule surge suppression rating
- Reliable Battery Backup
- Supports half load up to 13 min. and full load up to 4.5 min.
- Internal batteries designed for hot-swap field replacement
- 95% line-power efficiency rating saves money in energy costs
- Pre-Installed WEBCARDLX Network Interface
- Network interface supports simultaneous communications via built-in USB, DB9 serial/contact-closure and pre-installed WEBCARDLX network management card
- Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, Telnet, SSH, or Command Line.
- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network.
- Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status
- Reduce Service Calls with Auto Probe Autonomous Device Management. The Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA)
- 2 Load Banks with Switchable Outlets
- Can control 4 outlets remotely to reboot equipment or shed nonessential loads
- Automatic Voltage Regulation (AVR)
- Maintains 120V nominal output over input range of 83V-147V without using battery power
- EMI/RFI Line Noise Filtering
- Removes electromagnetic and radio frequency interference that can disrupt or damage equipment's performance
- Interactive LCD Screen
- Front-panel LCD signals operating mode, load level, voltage, battery charge and estimated runtimes
- Rotates for easy viewing in rack-mount or tower configurations
- Communications Ports
- USB and DB9 ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software (available via free download from www.tripplite.com/poweralert )
- EPO port supports emergency shutdown in large facilities
- Versatile Installation Options
- Hardware included for 4-post mounting in 2U of EIA-standard 19 in. rack
- Mounts on wall or 2-post rack with optional 2POSTRMKITWM accessory
- Mounts in upright tower position with optional 2-9USTAND accessory
Specifications
Specifications
Overview
| UPC Code | 37332178237 |
|---|---|
| UPS Type | Line-Interactive |
Input
| Rated input current (Maximum Load) | 12A |
|---|---|
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS Input Connection Type | 5-15P |
| Input Circuit Breakers | 15A |
| UPS Input Cord Length (ft.) | 10 |
| Recommended Electrical Service | 15A 120V |
Output
| Output Volt Amp Capacity (VA) | 1500 |
|---|---|
| Output kVA Capacity (kVA) | 1.5 |
| Output Watt Capacity (Watts) | 1350 |
| Output kW Capacity (kW) | 1.35 |
| Power Factor | 0.9 |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Frequency Compatibility | 60 Hz |
| Output Voltage Regulation (Line Mode) | -21%, +8% |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Load Management Receptacles | Two switchable two-outlet 5-15R load banks |
Battery
| Battery Type | Valve Regulated Lead Acid (VRLA) |
|---|---|
| Full Load Runtime (min.) | 4.5 min. (1350w) |
| Half Load Runtime (min.) | 13 min. (675w) |
| Expandable Runtime | No |
| DC System Voltage (VDC) | 36 |
Voltage Regulation
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 |
|---|---|
| Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
User Interface, Alerts & Controls
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
|---|---|
| Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset. |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Surge / Noise Suppression
| UPS AC Suppression Joule Rating | 570 |
|---|---|
| UPS AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
Communications
| Network Monitoring Port Description | Includes Pre-installed WEBCARDLX Network Management interface card. RJ45 Network port; Micro-USB Configuration/Console port; USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. |
|---|---|
| PowerAlert Software | For local monitoring via the UPS’s built-in Serial or USB communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert |
| Communications Cable | Micro-USB; USB; and DB9 cabling included |
| WatchDog Compatibility | Supports Watchdog application; OS and hard-reboot restart options for remote applications |
| EPO Port | RJ11 interface jack with 4 meter cable included. Supports normally open and normally closed EPO systems |
| SNMP Compatibility | SNMPv1; V2c; V3 |
| Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
| Network Speed | 10/100 Mbps |
| Communications Interface | DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled) |
Documents and Downloads
Documents and Downloads
- SMART1500RM2UN runtime chart
- Owner's Manual for SmartPro 2U Rackmount UPS
- Integrated Solutions Brochure (English)
- Auto Probe Solution for Monitoring and Rebooting Locked-Up Devices (English)
- SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)
- UPS Sizing
- Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
- UPS Systems Buying Guide
- Custom Products from Tripp Lite Are One Call Away
- Economy Mode Explained
- Product Videos
- Download images for this product
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
