Brand: Tripp-Lite
|
SKU:
509568
Tripp-Lite SMART1500RMXLN | SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD
Regular price
$2,273.08
Unit price
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Brand: Tripp-Lite
|
SKU:
509568
Regular price
$2,273.08
Unit price
Description
Description
Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise. Pre-installed WEBCARDLX network interface permits remote UPS management, including reboots.
Features
- Protects Mission-Critical Rack-Mounted Equipment
- Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
- Audible alarm signals loss of utility power, overload, low battery and fault conditions
- 10-ft. (3.05 m) power cord with 120V NEMA 5-15P input
- 0.9 power factor rating
- 570-joule surge suppression rating
- Reliable Battery Backup with Expandable Runtime
- Supports half load up to 14 min. and full load up to 4.9 min.
- Internal batteries designed for hot-swap field replacement
- 95% line-power efficiency rating saves money in energy costs
- Expandable runtime with optional external battery packs, such as Tripp Lite's BP36V15-2U
- Pre-Installed WEBCARDLX Network Interface
- Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH
- Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status
- Reduce Service Calls with Auto Probe Autonomous Device Management
- Auto Probe feature (Firmware 15.5.2 and greater) of the LX Platform Interface checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA)
- 8 NEMA 5-15R Outlets in 2 Load Banks
- 4 outlets are switchable to remotely reboot equipment or shed nonessential loads
- Automatic Voltage Regulation (AVR)
- Maintains 120V nominal output over input range of 83V-145V without using battery power
- EMI/RFI Line Noise Filtering
- Removes electromagnetic and radio frequency interference that can disrupt or damage equipment's performance
- Interactive LCD Screen
- Front-panel LCD signals operating mode, load level, voltage, battery charge and estimated runtimes
- Rotates for easy viewing in rack-mount or tower configurations
- Communications Ports
- USB and DB9 ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software (available via free download from www.tripplite.com/poweralert )
- EPO port supports emergency shutdown in large facilities
- Versatile Installation Options
- Hardware included for 4-post mounting in 2U of EIA-standard 19 in. rack
- Mounts on wall or 2-post rack with optional 2POSTRMKITWM accessory
- Mounts in upright tower position with optional 2-9USTAND accessory
Specifications
Specifications
Overview
| UPC Code | 37332178022 |
|---|---|
| UPS Type | Line-Interactive |
Input
| Rated input current (Maximum Load) | 12A |
|---|---|
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS Input Connection Type | 5-15P |
| Input Circuit Breakers | 15A |
| UPS Input Cord Length (ft.) | 10 |
| Recommended Electrical Service | 15A 120V |
Output
| Output Volt Amp Capacity (VA) | 1500 |
|---|---|
| Output kVA Capacity (kVA) | 1.5 |
| Output Watt Capacity (Watts) | 1350 |
| Output kW Capacity (kW) | 1.35 |
| Output Capacity Details | Output is reduced to 1200 watts maximum when used with external battery packs |
| Power Factor | 0.9 |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Frequency Compatibility | 60 Hz |
| Output Voltage Regulation (Line Mode) | -14%, +6% |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
Battery
| Battery Type | Valve Regulated Lead Acid (VRLA) |
|---|---|
| Full Load Runtime (min.) | 4.9 min. (1350w) |
| Half Load Runtime (min.) | 14 min. (675w) |
| Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
| Expandable Runtime | Yes |
Voltage Regulation
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
|---|---|
| Overvoltage Correction | Input voltages between 127 and 145 are reduced by 12% |
User Interface, Alerts & Controls
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
|---|---|
| Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Surge / Noise Suppression
| UPS AC Suppression Joule Rating | 570 |
|---|---|
| UPS AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
Communications
| Network Monitoring Port Description | Includes Pre-installed WEBCARDLX Network Management Card interface |
|---|---|
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert |
| Communications Cable | Micro-USB; USB and DB9 cabling included |
| WatchDog Compatibility | Supports Watchdog application; OS and hard-reboot restart options for remote applications |
| EPO Port | RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems |
| SNMP Compatibility | SNMP V1; V2c; V3 |
| Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
| Communications Interface | DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled) |
Documents and Downloads
Documents and Downloads
- SMART1500RMXLN runtime chart
- Owner's Manual for SmartPro 2U Rackmount UPS
- Owner's Manual Addendum for External Battery Packs (Multi-Language)
- Integrated Solutions Brochure (English)
- Auto Probe Solution for Monitoring and Rebooting Locked-Up Devices (English)
- SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)
- UPS Sizing
- Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
- UPS Systems Buying Guide
- Custom Products from Tripp Lite Are One Call Away
- Economy Mode Explained
- Product Videos
- Download images for this product
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.