Tripp-Lite SMX1000RT2U | SmartPro 230V 1kVA 900W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, DB9, 6 Outlets
Tripp-Lite SMX1000RT2U | SmartPro 230V 1kVA 900W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, DB9, 6 Outlets

Tripp-Lite SMX1000RT2U | SmartPro 230V 1kVA 900W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, DB9, 6 Outlets

Tripp-Lite 1000Va International Ups System Smartpro
Part Number: 565437
0 Review(s)
Write a Review
Availability:
$914.57
Retail Price:$981.29
Your Savings:$66.72(7%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, surges and line noise. Ideal solution for point-of-sale applications, VoIP systems and small business networks.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • Protects Mission-Critical Rack-Mounted Equipment
  • Provides fully regulated sine wave AC output for point-of-sale applications, VoIP systems and small business networks
  • Audible alarm signals loss of utility power, overload, low battery and fault conditions
  • 6 C13 outlets
  • C14 inlet accepts user-supplied AC power cord with country-specific plug
  • 350-joule surge suppression rating
  • Reliable Battery Backup
  • Supports half load up to 11.9 min. and full load up to 3.6 min.
  • Internal batteries designed for hot-swap field replacement
  • 97% line-power efficiency rating saves money in energy costs
  • 2 Load Banks with Switchable Outlets
  • Can control 4 outlets remotely to reboot equipment or shed nonessential loads
  • Automatic Voltage Regulation (AVR)
  • Maintains 230V nominal output over input range of 182V–278V without using battery power
  • EMI/RFI Line Noise Filtering
  • Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s performance
  • Interactive LCD Screen
  • Front-panel LCD signals voltage, battery and load statuses
  • Supports multiple advanced user setup and operating preferences
  • Rotates for easy viewing in rack-mount or tower configurations
  • Optional Network Management Cards
  • Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD
  • Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
  • PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
  • IP-based Auto Probe detects lost connectivity and restores service autonomously
  • Communications Ports
  • USB and DB9 ports enable data-saving unattended shutdown when used with Tripp Lite’s Power Alert software (available via free download at www.tripplite.com/poweralert)
  • EPO port supports emergency shutdown in large facilities
  • Versatile Installation Options
  • Hardware included for 4-post mounting in 2U of EIA-standard 19 in. rack
  • Mounts on wall or 2-post rack with optional 2POSTRMKITWM accessory
  • Mounts in upright tower position with optional 2-9USTAND accessory



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332119223
UPS TypeLine-Interactive



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load)4.8A
Nominal Input Voltage(s) Supported230V AC
UPS Input Connection TypeC14 inlet
UPS Input Connection DescriptionIEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Input Circuit Breakers10A
Input PhaseSingle-Phase



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA)1000
Output kVA Capacity (kVA)1
Output Watt Capacity (Watts)900
Power Factor0.9
Nominal Voltage Details230V nominal output in battery mode
Frequency Compatibility50 / 60 Hz
Frequency Compatibility DetailsAutomatic frequency selection
Output Voltage Regulation (Line Mode)+6%, -11%
Output Voltage Regulation (Battery Mode)+/- 5%
Included Output Power CablesIncludes 2 C13 to C14 output power cables



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Battery TypeValve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)3.6 min. (900w)
Half Load Runtime (min.)11.9 min (450w)
Expandable RuntimeNo
DC System Voltage (VDC)24



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 182 to 278
Overvoltage CorrectionInput voltages between 244 and 278 are reduced by 12%



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Front Panel LCD DisplayFront panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel OperationPower-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

UPS AC Suppression Joule Rating350
UPS AC Suppression Response TimeInstantaneous
EMI / RFI AC Noise SuppressionYes



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Management CardsSNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX
Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications CableUSB and DB9 cabling included
WatchDog CompatibilitySupports Watchdog application; OS and hard-reboot restart options for remote applications
Communications InterfaceDB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

SMX1000RT2U runtime chartClick to View
Owner's Manual for 230V 2U Rackmount UPS Systems (Multi-language)Click to View
Installation Guide for Select Rackmount UPSClick to View
PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface User's Guide (English)Click to View
Owner's Manual Addendum for External Battery Packs (Multi-Language)Click to View
UPS 230V Brochure (English)Click to View
Integrated Solutions Brochure (English)Click to View
UPS Systems 230V Brochure (Chinese)Click to View
EC DeclarationClick to View
Piraeus Bank in Greece Case Study - ATM/kiosk Protection (English)Click to View
UPS SizingClick to View
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server ApplicationsClick to View
UPS Systems Buying GuideClick to View
Custom Products from Tripp Lite Are One Call AwayClick to View
Economy Mode ExplainedClick to View

Recently Viewed Items