Description
Description
Tripp-Lite SU20KRT-1TF | SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch
Features
- Tripp Lite SU20KRT-1TF 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 14U total rack/tower configuration
- Unique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and under
- Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
- Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets
- Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V & 120V nominal
- Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)
- Expandable runtime with optional external battery packs
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries
- Intelligent battery management system with temperature-compensated charging extends battery life
- HID-compliant USB interface
- USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (6 required)
- Optional 2-9USTAND supports upright tower placement (2 required)
- Supports Emergency Power Off (EPO) via built-in interface
- Front panel LEDs and LCD readout with scroll controls
- LED / LCD display panel rotates for viewing in rackmount or tower configurations
- External battery packs are field replaceable and hot swappable
Specifications
Specifications
Overview
| UPC Code | 37332158260 |
|---|---|
| UPS Type | On-Line |
Input
| Rated input current (Maximum Load) | 108A (208V), 93.6A (240V) |
|---|---|
| Nominal Input Voltage(s) Supported | 208V AC; 240V AC |
| UPS Input Connection Type | Hardwire |
| UPS Input Connection Description | 3 wire single phase input (L1, L2, G) |
| Recommended Electrical Service | 125A @ 208V, or 240V (L1, L2, G) |
| Input Phase | Single-Phase |
Output
| Output Volt Amp Capacity (VA) | 20000 |
|---|---|
| Output kVA Capacity (kVA) | 20 |
| Output Watt Capacity (Watts) | 18000 |
| Output kW Capacity (kW) | 18 |
| Output Capacity Details | Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less |
| Power Factor | 0.9 |
| Crest Factor | 3:1 |
| Nominal Voltage Details | This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting) |
| Frequency Compatibility | 60 Hz |
| Frequency Compatibility Details | Output frequency regulation +/- 0.05Hz (free running) |
Battery
| Battery Type | Valve Regulated Lead Acid (VRLA) |
|---|---|
| Full Load Runtime (min.) | 4.3 minutes (18,000 watts) |
| Half Load Runtime (min.) | 12.5 minutes (9000 watts) |
| Expandable Battery Runtime | Runtime is expandable with external battery packs |
| Expandable Runtime | Yes |
Voltage Regulation
| Voltage Regulation Description | 2% output voltage regulation in standard online, double-conversion mode |
|---|---|
| Overvoltage Correction | Corrects overvoltages up to 300V |
User Interface, Alerts & Controls
| Front Panel LCD Display | Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual) |
|---|---|
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement |
| Alarm Cancel Operation | Alarm cancel switch |
Surge / Noise Suppression
| UPS AC Suppression Joule Rating | 2565 |
|---|---|
| UPS AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
Communications
| Network Management Cards | SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD |
|---|---|
| Network Monitoring Port Description | Applications utilizing any supported network management card option; require the installation of two of the same model network card – install one card per included UPS power module; RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module |
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert |
| Communications Cable | USB; DB9 serial and EPO cables included |
| WatchDog Compatibility | Supports Watchdog application; OS and hard-reboot restart options for remote applications |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Documents and Downloads
Documents and Downloads
- SU20KRT-1TF runtime chart
- Owner's Manual for 8 and 10kVA Parallel PDUs (Multi-language)
- Owner's Manual for BP Battery (Multi-language)
- Owner's Manual for SU6000XFMR2U SmartOnline 6kVA Transformer
- Owner's Manual for SmartOnline 8kVA-10kVA UPS (Multi-language)
- Owner's Manual Addendum for SU6000XFMR2U (English)
- Single-Phase UPS Systems Visio Stencil
- Single-Phase UPS Systems Visio Stencil Preview
- Integrated Solutions Brochure (English)
- EC Declaration
- EC Declaration
- EC Declaration
- Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
- UPS Sizing
- UPS Systems Buying Guide
- Custom Products from Tripp Lite Are One Call Away
- Economy Mode Explained
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.