12% off
Tripp-Lite SU5000RT4U SmartOnline 5kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 208/120V or 240/120V Nema Outlets, Split-Phase Input
Tripp-Lite SU5000RT4U SmartOnline 5kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 208/120V or 240/120V Nema Outlets, Split-Phase Input

Tripp-Lite SU5000RT4U SmartOnline 5kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 208/120V or 240/120V Nema Outlets, Split-Phase Input

0
0
5

$3,757.37
$4,251.41
$494.04(12%)
TRL-SU5000RT4U
Tripp-Lite
Tripp Lite 5kVA SmartOnline Hot-Swappable Modular Rack/Tower UPS. 5000VA on-line, double-conversion UPS for server, network and telecommunications equipment. Maintains battery-derived AC output during blackouts with active, full-time power conditioning. Fault tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions. Single all-in-one housing installs in 4 rack spaces (4U). Upright tower installation with optional 2-9USTAND accessory. 2-post rackmount installation with optional 2POSTRMKITWM. Full-time sine wave output within 3% of selectable 208/120 or 240/120V AC. Corrects brownouts and overvoltages from 65V to 140V (L-N). Expandable runtime with optional external battery packs. Dual-conversion UPS converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include combination RS-232 enabled and contact closure serial port, enhanced USB port and SNMPWEBCARD slot. Includes USB and DB9 serial ports. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm. Self test. 4-post rackmount accessories. Includes NEMA L14-30P split phase 4 wire input plug and 12 total output receptacles (2 L6-30R, 2 L6-20R and 8 5-15/20R). Input cord and outlets are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment. Optional SUPDM56HW detachable backplate accessory enables hardwire input-output connections to the UPS. Additional external Power Distribution Unit (PDU) options available. Internal batteries and optional external battery packs are field replaceable and hot swappable. Attractive all-black color scheme. $250,000 connected equipment insurance.

Features
  • True on-line, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
  • 5000VA/3800 watt output power capacity with dual voltage output of 208/120 or 240/120V
  • 4U all-in-one high power density housing supports rackmount installation in only 4 rack spaces
  • Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
  • Input cord and outlets are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment
  • Optional SUPDM56HW detachable backplate accessory enables hardwire input-output connections to the UPS
  • Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical servers, networking and telecommunications equipment
  • Maintains output within 3% of selected 208/120 or 240/120V nominal voltage during brownouts and overvoltages
  • Supports connected equipment during blackouts for 14/6 minutes at half/full load levels, runtime is further expandable with optional external battery packs
  • Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
  • Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot
  • Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
  • Communication ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
  • Includes USB and DB9 serial ports. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability.
  • HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
  • Built-in Emergency Power Off (EPO) interface with cable
  • Includes 12 built-in output receptacles (2 L6-30R, 2 L6-20R, 8 NEMA 5-15/20R)
  • L14-30P split phase, 4 wire plug-in connection (featured on included detachable PDU). Optional SUPDM56HW hardwire input/output PDU available separately
  • Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions
  • Front panel switches enable power on/off control, self-test and alarm cancel functions
  • Included adjustable mounting rails support installation in 4 post 19-inch rack enclosures
  • Optional 2-9USTAND set of tower stands supports upright tower installation
  • Optional 2POSTRMKITWM accessory enables 2-post rackmount installation
  • UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user is required
  • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
  • Detachable PDU with built-in manual bypass switch enables hot-swappable UPS replacement without powering off connected equipment

    Specs
  • Manufacturer Tripp-Lite
  • Category New
  • Output Volt Amp Capacity (VA) 5000
  • Output kVA capacity (kVA) 5
  • Output Watt Capacity (watts) 3800
  • Output kW capacity 3.8
  • Output power factor 0.8
  • Crest Factor 3:1
  • Nominal Output Voltage(s) Supported 120V; 208V; 240V
  • Nominal Voltage details 240/120V or 208/120V split phase output
  • Frequency compatibility 60 Hz
  • Output voltage regulation (line mode) +/- 3%
  • Output voltage regulation (Economy line mode) +/- 10%
  • Output voltage regulation (Battery mode) +/- 3%
  • Built-in UPS output receptacles 8 5-15/20R outlet(s); 2 L6-20R outlet(s); 2 L6-30R outlet(s)
  • Output circuit breaker 20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered
  • Output AC waveform (AC mode) Sine wave
  • Output AC waveform (battery mode) Pure Sine wave
  • Rated input current (at maximum load) 21A
  • Nominal Input Voltage(s) Supported 208V AC / 120V AC (4 wire split single phase); 240V AC /120V AC (4 wire split single phase)
  • UPS input connection type L14-30P
  • UPS input connection description 4 wire split-phase input (L1, L2, N, G)
  • UPS Input cord length (ft.) 10
  • UPS Input cord length (m) 3
  • Recommended Electrical Service 30A 208/120V Split Phase
  • Input cord length (m) 3
  • Installation form factors supported with included accessories 4 post 19 inch rackmount (mounting rail kit included)
  • Installation form factors supported with optional accessories 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
  • Primary form factor Rackmount
  • UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 7 x 17.5 x 30.8
  • UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 17.8 x 44.4 x 78.1
  • Installed whole system maximum rack depth (inches) 30.8
  • Installed whole system maximum rack depth (cm) 78.1
  • Installed whole system total rack space height (rack spaces) 4U
  • Secondary form factor Tower (requires 2-9USTAND)
  • UPS dimensions details 4U UPS with internal batteries
  • UPS Shipping dimensions (height x width x depth / inches) 13.2 x 37 x 23
  • UPS Shipping dimensions (height x width x depth / cm) 33.7 x 94 x 58.4
  • Cooling method Fan
  • Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity 0 to 95%, non-condensing
  • AC mode BTU / hr. (full load) 1435.6
  • Battery mode BTU / hr. (full load) 1277.8
  • Operating Elevation (ft) 0-3000m (0 to 10,000 ft.)
  • Audible Noise 60 dBA at front side 1 meter
  • Operating Elevation (m) 0-3000 m
  • There are no reviews for this product!

    Recently Viewed Items

    The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.