Tripp-Lite SU60K | SmartOnline 120/208V 3-Phase Wye 60kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America
Tripp-Lite SU60K | SmartOnline 120/208V 3-Phase Wye 60kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

Tripp-Lite SU60K | SmartOnline 120/208V 3-Phase Wye 60kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

Tripp-Lite 60Kva/48Kw, 208V, 3Ph, 4W, Modular Ups P
Part Number: 444075
0 Review(s)
Write a Review
Availability:
$32,786.79
Retail Price:$33,974.44
Your Savings:$1,187.65(3%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Tripp Lite's SU60K (60kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In an N+1 configuration, the SU60K features three self-contained, redundant 20kVA power modules that can be hot-swapped (with the load powered) if maintenance is required. Connect two SU60K models in parallel (1+1 configuration) to provide fail-safe redundancy (two 60kVA models supporting a 60kVA load) or to increase capacity (two 60kVA models supporting an 120kVA load). The SU60K provides mission-critical equipment with the highest level of power protection available. Large capacity 60,000VA/48,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. The SU60K's high input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create less than 3% input Total Harmonic Distortion (THDi). With SU60K's low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to their equipment load (a 1:1 ratio). Extremely efficient operation (up to 96%) saves money by lowering electricity consumption. Hardwire input and output connections. SU60K features 120/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 94-150/163-260V AC. Frequency is 50 or 60 Hz (auto-selectable). SU60K features a single small-footprint tower power module. A stand-alone hardwired external battery module (Models BP480V26B or BP480V40C with matching battery cabinets, available separately) is required for operation and to provide battery backup support. Additional external BP480V26B or BP480V40C battery modules can be connected for extended runtime. Additional battery cabinets for extended runtime solutions also available; contact Tripp Lite for more information. A manual bypass breaker as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance. A built-in RS-232 communication port works with PowerAlert Software to provide shutdown commands and condition reporting. An accessory slot accepts an optional network management card option. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions. The LCD display includes a real-time event log screen with up to 500 events listed. A dynamic battery management screen optimizes battery function to lengthen service life and allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities. A start-up service program is recommended to enhance the reliability of the installation.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • N+1 configuration: three self-contained, redundant 20kVA power modules can be hot-swapped (with the load powered) if maintenance is required
  • 1+1 configuration: connect two SU60K models in parallel to provide fail-safe redundancy or to increase capacity
  • High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create low input Total Harmonic Distortion (THDi)
  • Extremely efficient operation (up to 96%) saves money by lowering electricity consumption
  • True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
  • 60,000VA/48,000W power capacity with 3-phase, hardwire 120/208VAC input/output connections
  • Features a wide input voltage correction range: 94-150/163-260VAC
  • Precision +/-1% output voltage regulation
  • A stand-alone hardwired external battery module (Models BP480V26B and BP480V40C, available separately from Tripp Lite) is required for operation and to provide battery backup support. Additional external battery modules can be connected for extended runtime.
  • Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
  • Dynamic battery management screen optimizes battery function to lengthen service life and allows cold restart of UPS
  • Serial port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
  • Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD and MODBUSCARD
  • Emergency Power Off button turns UPS output OFF and disables Bypass output
  • Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities
  • Start-up service program is recommended to enhance the reliability of the installation



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332141323
UPS TypeOn-Line



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load)125A (per phase, online)
Nominal Input Voltage(s) Supported120/208V 3-PH Wye
Nominal Input Voltage Description3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS Input Connection TypeHardwire
Input Phase3-Phase



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA)60000
Output kVA Capacity (kVA)60
Output Watt Capacity (Watts)48000
Output kW Capacity (kW)48
Power Factor0.8
Crest Factor3:1
Frequency Compatibility50 / 60 Hz
Output Voltage Regulation (Line Mode)+/- 1%
Output Voltage Regulation (Battery Mode)+/- 1%
Output AC Waveform (AC Mode)Sine wave



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Expandable Battery RuntimeBattery set sold separate
Expandable RuntimeYes
Expandable Runtime DescriptionExternal battery pack wiring is contractor supplied
External Battery Pack CompatibilityBP480V200 ;  BP480V26B ;  BP480V300 ;  BP480V400 ;  BP480V40C ;  BP480V500
DC System Voltage (VDC)+/- 240VDC



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage CorrectionMaintains continuous operation without using battery power during overvoltages to 150 / 260 (3-Phase, 4-Wire, wye), reducing output within 1% of nominal



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

SwitchesON button turns UPS's inverter ON. OFF button turns UPS's inverter OFF. LCD Display Control Buttons browses through and selects items displayed on LCD screen. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass breaker bypasses the UPS's inverter during maintenance.
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch
Audible AlarmAlarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating4675
AC Suppression Response TimeInstantaneous



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Management CardsSNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications CableDB9 cabling included
Communications InterfaceDB9 Serial; Slot for SNMP/Web interface



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

SU60K runtime chartClick to View
Owner's Manual for 3-Phase UPS (English)Click to View
3-Phase UPS Systems Visio StencilClick to View
3-Phase UPS Systems Visio Stencil PreviewClick to View
Integrated Solutions Brochure (English)Click to View
UPS SizingClick to View
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server ApplicationsClick to View
UPS Systems Buying GuideClick to View
Custom Products from Tripp Lite Are One Call AwayClick to View
Economy Mode ExplainedClick to View
Product VideosClick to View

Recently Viewed Items