Tripp-Lite SU8000RT3UTAA | SmartOnline 208/240V 8kVA On-Line UPS – Double Conversion, 7.2kW, 6U, Network Card Option, TAA Compliant
Tripp-Lite SU8000RT3UTAA | SmartOnline 208/240V 8kVA On-Line UPS – Double Conversion, 7.2kW, 6U, Network Card Option, TAA Compliant

Tripp-Lite SU8000RT3UTAA | SmartOnline 208/240V 8kVA On-Line UPS – Double Conversion, 7.2kW, 6U, Network Card Option, TAA Compliant

Part Number: 9810688
0 Review(s)
Write a Review
Availability:
$7,582.99
Retail Price:$8,136.24
Your Savings:$553.25(7%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

TAA-compliant UPS protects connected equipment against damage due to blackouts, brownouts, surges and line noise.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss
  • This TAA-compliant UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring a 7200W capacity, high 0.9 power factor, true on-line operation with pure sine wave output and zero transfer time to battery, the SmartOnline SU8000RT3UTAA provides the highest level of battery backup and AC power protection for critical server, network and telecom equipment.
  • Reliable, Expandable Battery Backup
  • UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The external battery provides 13.5 minutes of support at half load and 5.5 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. For mission-critical applications demanding continuous uptime, the double-conversion UPS can provide expandable runtime with optional external battery packs, such as Tripp Lite’s field-replaceable, hot-swappable BP240V10RT3UTAA (sold separately). A battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries.
  • Easily Hot-Swappable with No Expensive Service Calls or Downtime Needed
  • With its detachable PDU, the SU8000RT3UTAA is easily hot-swappable by a user of any skill set. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. When making repairs or replacing a battery, no lengthy service calls or downtime are necessary.
  • Economy Mode Helps the Environment and Your Cash Flow
  • Operating with a high 96% efficiency in optional economy mode, the SU8000RT3UTAA significantly reduces BTU heat output and operating energy costs.
  • Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
  • Front-panel LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status at a glance. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration.
  • Optional WEBCARDLX Network Interface Offers 24/7 Access
  • An accessory slot accommodates the optional Java-free HTML5-based WEBCARDLX interface, which enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime.
  • Advanced Communications Ports
  • USB and DB9 ports (cables are included) enable data-saving unattended shutdown of connected systems when used with Tripp Lite’s free downloadable PowerAlert software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions.
  • Versatile Installation Options
  • Hardware is included for mounting the double-conversion UPS system in 6U of space in an EIA-standard 19-inch 4-post rack. Use two optional 2POSTRMKITHD kits for 2-post rack mounting or the included 2-9USTAND for mounting in an upright tower position.
  • TAA-Compliant UPS for GSA Schedule Purchases
  • The SU8000RT3UTAA is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
  • 2-Year Warranty, $250K Ultimate Lifetime Insurance and Environmentally Responsible Design
  • The SU8000RT3UTAA comes with a 2-year warranty and $250,000 of Ultimate Lifetime Insurance for any connected components damaged by a power surge (U.S., Canada and Puerto Rico only). It’s manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite’s commitment to environmental responsibility.



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332223715
UPS TypeOn-Line



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load)46A (200V), 44.2A (208V), 41.8A (220V), 40A (230V), 38.3A (240V)
Nominal Input Voltage(s) Supported200V AC; 208V AC; 240V AC
UPS Input Connection TypeHardwire
UPS Input Connection Description3 wire single phase input (L1, L2, G)
Recommended Electrical Service50A
Input PhaseSingle-Phase



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA)8000
Output kVA Capacity (kVA)8
Output Watt Capacity (Watts)7200
Output kW Capacity (kW)7.2
Output Capacity DetailsSupports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor0.9
Crest Factor3:1
Nominal Voltage DetailsVoltage selection via front panel LCD interface
Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility DetailsOutput frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (No de-rating); Output frequency regulation +/- 0.05Hz (free running)



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Battery TypeValve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)5.5 min. (7200w)
Half Load Runtime (min.)13.5 min. (3600w)
Expandable Battery RuntimeSupports extended runtime with optional external battery packs
Expandable RuntimeYes



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation Description2% output voltage regulation in standard online, double-conversion mode
Overvoltage CorrectionCorrects overvoltages up to 300V



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Front Panel LCD DisplaySelectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
Switches2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
Alarm Cancel OperationAlarm cancel switch



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

UPS AC Suppression Joule Rating2565
UPS AC Suppression Response TimeInstantaneous
EMI / RFI AC Noise SuppressionYes



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Management CardsSNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD
Network Monitoring Port DescriptionAdditional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications CableUSB; DB9 serial and EPO cables included
WatchDog CompatibilitySupports Watchdog application; OS and hard-reboot restart options for remote applications
Communications InterfaceDB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

SU8000RT3UTAA runtime chartClick to View
Owner's Manual for SUPDMB710/HWClick to View
Owner's Manual for BP Battery (Multi-language)Click to View
Installation Guide for Select Rackmount UPSClick to View
Owner's Manual for SmartOnline 8kVA-10kVA UPS (Multi-language)Click to View
Owner's Manual Addendum for External Battery Packs (Multi-Language)Click to View
Single-Phase UPS Systems Visio StencilClick to View
Single-Phase UPS Systems Visio Stencil PreviewClick to View
EC DeclarationClick to View
EC DeclarationClick to View
EC DeclarationClick to View
Product VideosClick to View
Download images for this productClick to View

Recently Viewed Items