Tripp-Lite SV120KL | SmartOnline SV Series 120kVA Large-Frame Modular Scalable 3-Phase On-Line Double-Conversion 208/120V 50/60 Hz UPS System
Tripp-Lite SV120KL | SmartOnline SV Series 120kVA Large-Frame Modular Scalable 3-Phase On-Line Double-Conversion 208/120V 50/60 Hz UPS System

Tripp-Lite SV120KL | SmartOnline SV Series 120kVA Large-Frame Modular Scalable 3-Phase On-Line Double-Conversion 208/120V 50/60 Hz UPS System

Part Number: 9810696
0 Review(s)
Write a Review
Availability:
$60,827.49
Retail Price:$65,265.51
Your Savings:$4,438.02(7%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

3-phase 120kVA UPS system offers network-grade power protection in a highly configurable, modular and scalable large-chassis rack-width frame. Pre-installed WEBCARDLX network interface allows full remote access 24/7.


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • 120kVA 108kW 3-Phase Large-Chassis UPS System
  • Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring
  • Dual hardwire input design enables operation from up to 2 power sources
  • Network-grade sine-wave AC output with 1% output voltage regulation and less than 1.5% output total harmonic distortion
  • Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards
  • High 0.9 power factor for maximum power to the connected load
  • Batteries not included—external ±120VDC battery cabinets, such as Tripp Lite’s BP240V370, sold separately
  • Pre-Installed WEBCARDLX Network Interface
  • Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH
  • Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
  • Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status
  • No Java required
  • Modular, Scalable Design for Maximum Flexibility
  • Modular configuration with hot-swappable power modules enables easy and fast maintenance with zero downtime
  • Open slots for up to 2 additional 20kVA SV20PM power modules accommodate increased capacity up to 140kVA with N+1 fault tolerance
  • Optional Economy Mode
  • Up to 99% efficient in optional economy mode to lower operating and cooling costs
  • Wide Input/Narrow Output Voltage Operating Range
  • Enables full continuous online operation during brownouts as low as 156V and overvoltages up to 253V
  • Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode
  • Advanced IGBT Inverter with Digital Signal Processor (DSP) Technology
  • Provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity
  • Automatic and Manual Bypass Options
  • Keep connected equipment operational during routine maintenance or critical power module failure



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332209856
UPS TypeOn-Line



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load)SV120KL 120kVA Configuration: 360A; Maximum 140kVA Large Chassis Configuration: 420A; 330A maximum inrush current
Nominal Input Voltage(s) Supported120/208V 3-PH Wye; 127/220V 3-PH Wye
Nominal Input Voltage DescriptionSet of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
UPS Input Connection TypeHardwire
Input Circuit BreakersMAIN and ALTERNATE AC inputs are each protected by 630A 3 pole magnetic breakers
Input Phase3-Phase



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA)120000
Output kVA Capacity (kVA)120
Output Watt Capacity (Watts)108000
Output kW Capacity (kW)108
Output Capacity DetailsOVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
Power Factor0.9
Crest Factor3:1
Nominal Voltage DetailsOutput THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility DetailsAuto-selectable, user adjustable



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Full Load Runtime (min.)Batteries sold separate; Runtime is dependent on battery pack quantity and load level
Expandable Battery RuntimeSupports extended runtime with optional external battery packs; 600A 3 pole 250VDC breaker recommended for external battery
Expandable RuntimeYes
Expandable Runtime DescriptionExternal battery pack wiring is contractor supplied
External Battery Pack CompatibilityBP240V370 ;  BP240V370NB ;  EBP240V2502 ;  EBP240V2502NB ;  EBP240V3502 ;  EBP240V3502NB ;  EBP240V5002 ;  EBP240V5002NB ;  EBP240V6002 ;  EBP240V6002NB ;  EBP240V6003 ;  EBP240V6003NB



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage CorrectionMaintains continuous output in online mode, without using battery power, during overvoltages to 253V (Ph-Ph), reducing output to within 1% of selected 208/120V, 220/127V nominal output voltage



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Front Panel LCD Display145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
SwitchesFront panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
Alarm Cancel OperationAudible alarms can be muted using on-screen prompts



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating2496
AC Suppression Joule Rating Details2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
AC Suppression Response TimeInstantaneous



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Management CardsWEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV
Network Monitoring Port DescriptionIncludes pre-installed Tripp Lite WEBCARDLX network interface
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications CableDB9 cabling included
SNMP CompatibilityIncludes pre-installed  WEBCARDLX  network interface card
Communications InterfaceDB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

SV120KL runtime chartClick to View
Owner's Manual for SmartOnline 208V SV-Series 3-Phase Modular UPS Systems (Multi-language)Click to View
User's Guide for WEBCARDLX PowerAlert Device Manager (English)Click to View
LX Firmware Update Instructions (English)Click to View
Instruction Sheet for Tripp Lite Networked Device Mass Configuration Utility (English)Click to View
Instruction Sheet for PowerAlert Mass Updater Utility (English)Click to View
PowerAlert Device Manager (PADM) 20.0.0 Command Line InterfaceClick to View
PowerAlert Device Manager (PADM) 20.0.0Click to View
Owner's Manual for WEBCARDLX (English)Click to View
Owner's Manual for WEBCARDLX (Multi-language)Click to View
User's Guide for PowerAlert Network Shutdown Agent PANSA (English)Click to View
User's Guide for PowerAlert Network Management System (PANMS) (English)Click to View
3-Phase UPS Systems Visio StencilClick to View
3-Phase UPS Systems Visio Stencil PreviewClick to View
SV Series 208V Large Frame Submittal DrawingClick to View
SmartOnline 3-Phase UPS System Brochure (English)Click to View
SmartOnline SV 3-Phase UPS System Brochure (English)Click to View
SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)Click to View
EC DeclarationClick to View
Product VideosClick to View