Tripp-Lite SVX90KM3P5B | SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double-Conversion Medium-Frame UPS System, 5 Battery Modules
Tripp-Lite SVX90KM3P5B | SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double-Conversion Medium-Frame UPS System, 5 Battery Modules

Tripp-Lite SVX90KM3P5B | SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double-Conversion Medium-Frame UPS System, 5 Battery Modules

Part Number: 9810735
0 Review(s)
Write a Review
Availability:
$47,382.59
Retail Price:$50,839.67
Your Savings:$3,457.08(7%)
  • Low prices.

    Price match guarantee

  • In-House Experts.

    We know our products

  • Easy Returns.

    Quick & Hassle Free

  • Superior Selection.

    Extensive product catalog

Tripp-Lite SVX90KM3P5B | SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double-Conversion Medium-Frame UPS System, 5 Battery Modules


https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • Tripp Lite's SVX90KM3P5B 90kVA/90kW SmartOnline UPS offers network-grade power protection in a highly configurable medium-frame modular, scalable form factor
  • Includes 3 SVX30PM 30kW power modules for 90kVA total capacity; Open slots for 1 additional SVX30PM 30kW power module enable enhanced N+1 redundancy
  • Included batteries support a full load of 90kW for 4.2 minutes and half load of 45kW for 8.8 minutes; Extended runtime is available with the addition of any number of supported external battery packs (sold separately)
  • Supports 220/380, 230/400 or 240/415V AC, 3-Phase Wye 4-Wire plus Earth Hardwire input and output wiring
  • Tested to CE for worldwide applications
  • Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
  • PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
  • Serial port enables unattended shutdown and UPS monitoring ability
  • Modular configuration with hot-swappable power modules enables easy and fast maintenance with zero downtime
  • Wide input voltage operating range enables full continuous online operation during brownouts as low as 120V (Ph-N) and overvoltages up to 276 (Ph-N)
  • Narrow output voltage operating range regulates output voltage within 1% of the selected 220/230/240 nominal output voltage in online, double-conversion mode
  • Over 95% efficient in online, double-conversion mode and over 99% efficient in optional economy-mode enables reduced operating and cooling costs
  • Less than 3% input Total Harmonic Distortion (THDi) prevents the need to oversize generator systems relative to UPS capacity
  • Dual hardwire input design enables operation from one or two input power sources
  • Front panel combination LCD/LED display offers full UPS condition and status reporting plus additional configuration options



https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code37332194374
UPS TypeOn-Line



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load)110A Maximum
Nominal Input Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Nominal Input Voltage DescriptionSet of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
UPS Input Connection TypeHardwire
Input Circuit BreakersMAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers
Input Phase3-Phase



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA)90000
Output kVA Capacity (kVA)90
Output Watt Capacity (Watts)90000
Output kW Capacity (kW)90
Output Capacity DetailsOVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
Power Factor1
Crest Factor03:01:00
Nominal Voltage DetailsOutput THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility DetailsAuto-selectable, user adjustable



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Full Load Runtime (min.)4.2 minutes (90kW)
Half Load Runtime (min.)8.8 minutes (45kW)
Expandable Battery RuntimeSupports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery
Expandable RuntimeYes
Expandable Runtime DescriptionExternal battery pack wiring is contractor supplied; All external battery configurations require the disconnection of internal battery modules



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage CorrectionMaintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage



https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Front Panel LCD Display145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
SwitchesFront panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
Alarm Cancel OperationAudible alarms can be muted using on-screen prompts



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating2496
AC Suppression Joule Rating Details2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
AC Suppression Response TimeInstantaneous



https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Management CardsWEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV
Network Monitoring Port DescriptionIncludes pre-installed Tripp Lite WEBCARDLX network interface
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications CableDB9 cabling included
SNMP CompatibilityIncludes pre-installed  WEBCARDLX  network interface card
Communications InterfaceDB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface



https://www.alldataresource.com/assets/images_commscope/pdf.jpg

Documents and Downloads

SVX90KM3P5B runtime chartClick to View
LX Firmware Update Instructions (English)Click to View
User's Guide for WEBCARDLX PowerAlert Device Manager (English)Click to View
Conduit Box Installation Instructions (Multi-language)Click to View
Instruction Sheet for PowerAlert Mass Updater Utility (English)Click to View
Instruction Sheet for Tripp Lite Networked Device Mass Configuration Utility (English)Click to View
PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface User's Guide (English)Click to View
Owner's Manual for WEBCARDLX (English)Click to View
User's Guide for PowerAlert Network Shutdown Agent PANSA (English)Click to View
User's Guide for PowerAlert Network Management System (PANMS) (English)Click to View
3-Phase UPS Systems Visio StencilClick to View
3-Phase UPS Systems Visio Stencil PreviewClick to View
SV Series 400V Medium Frame Submittal DrawingClick to View
SmartOnline SVX 3-Phase UPS System Brochure (English)Click to View
SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)Click to View
EC Declaration 1. SVX30KL 2. SVX60KL 3. SVX90KL 4. SVX120KL 5. SVX150KL 6. SVX180KL 7. SVX210KL7P 8. SVX210KL8PClick to View
PADM20 High-Level OverviewClick to View
PowerAlert Device Manager v20Click to View
PowerAlert Device Manager v20 for Networked Tripp Lite UPS SystemsClick to View
New Auto-Probe Feature on UPS Systems and PDUsClick to View