{"title":"Other Accessories","description":null,"products":[{"product_id":"hoffman-ahci10e-corrosion-inhibitor-emitter-10-cu-ft-package-quantity-12","title":"Hoffman AHCI10E | Corrosion Inhibitor Emitter, 10 cu.ft., package quantity 12","description":"\u003cp\u003eUse Corrosion Inhibitors to protect electronic components inside the enclosure against corrosion. It is simple and economical to use; no surface preparation is required and puts protected equipment to use immediately without degreasing or coating removal. Each inhibitor contains a special chemical combination that vaporizes and condenses on all surfaces in an enclosed area. Vapors will redeposit as needed in the event of condensation of moisture on surfaces. These vapors reach every part of an enclosure, protecting all interior components. They do not interfere with electrical, optical or mechanical surface properties. Protection is effective even in salt-water atmospheres. The AHCI5E and AHCI10E emitters have additional red-metal inhibitors for further protection. The normal useful life-span of Hoffman corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since Corrosion Inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors. Each Corrosion Inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). Hoffman corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e\u003cp\u003eThe normal useful life-span of HOFFMAN corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since HOFFMAN corrosion inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors.\u003c\/p\u003e\u003cp\u003eEach nVent HOFFMAN corrosion inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). HOFFMAN corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200747512043,"sku":"488301","price":51.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHCI10E_Corrosion_Inhibitor_Emitter.jpg?v=1786505602"},{"product_id":"hoffman-abs-operator-adapter-for-universal-cutout-allen-bradley-small-handle","title":"Hoffman ABS | Operator Adapter for Universal Cutout, Allen Bradley, Small Handle","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200804200683,"sku":"650554","price":434.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ABS_Operator_Adapter.jpg?v=1786508796"},{"product_id":"hoffman-p1032cn-cage-nut-package-10-32-steel-qty-20","title":"Hoffman P1032CN | Cage Nut Package, # 10-32, Steel, Qty 20","description":"\u003cp\u003eThe Cage Nut Packages are for use with square-hole rack angles. They simply snap into the holes.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200804724971,"sku":"351668","price":67.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_P1032CN_Cage_Nut_Package.jpg?v=1786508798"},{"product_id":"hoffman-ubp-blank-adapter-plate-mild-steel","title":"Hoffman UBP | Blank Adapter Plate, Mild Steel","description":"\u003cp\u003eUsed to cover flange cutouts in disconnect enclosures when disconnects are not installed. This greatly increases the versatility of disconnect enclosures, enabling them to also be used as regular Type 12 enclosures. If the UBP model is used, the disconnect enclosure can be used as a regular Type 4 enclosure. HOFFMAN adapter plates are made from heavy gauge steel and have an oil-resistant gasket to maintain a dust-tight and oil-tight seal. Mounting hardware and instructions are included. Door hardware is not furnished with blank adapter plate. Door hardware must be ordered separately from the disconnect manufacturer when using catalog numbers A22BAP on Bulletin A22 Enclosures and A3456BAP on Bulletin A25 Enclosures.\u003c\/p\u003e\u003cp\u003eA22BAP will fit all Bulletin A22 enclosures except A48AB3812 and A60AB3812A2LP.\u003c\/p\u003e\u003cp\u003eA3456BA will fit all Bulletin A25 enclosures except A60SA3812A24LP.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200805544171,"sku":"654862","price":211.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_UBP_Blank_Adapter_Plate.jpg?v=1786508814"},{"product_id":"hoffman-anm5-clip-nut-package-for-rack-mounting-angel-20-pcs-m5-steel","title":"Hoffman ANM5 | Clip Nut Package for Rack Mounting Angel, 20 pcs, M5, Steel","description":"\u003cp\u003eTwenty plated clip nuts fit all rack-mounting angles with .281-in. (7-mm) diameter holes (through-hole type).\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200806625515,"sku":"459807","price":151.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ANM5_Clip_Nut_Package.jpg?v=1786508832"},{"product_id":"hoffman-abbsc-operator-adapter-for-universal-cutout-abb-controls-small-handle","title":"Hoffman ABBSC | Operator Adapter for Universal Cutout, ABB Controls, Small Handle","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200820945131,"sku":"650543","price":434.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ABBSC_Operator_Adapter.jpg?v=1786509101"},{"product_id":"hoffman-a1001yzumc1-small-volume-type-y-and-z-purging-pressurization-system-2cf-class-1","title":"Hoffman A1001YZUMC1 | Small-Volume Type Y and Z Purging\/Pressurization System, 2CF, Class 1","description":"\u003cp\u003eSmall-Volume Purging\/Pressurization Systems are an alternative to NEMA Type 7 or 9 enclosures. The C1 model allows general-purpose enclosures, up to two cubic feet, to be used in certain Class 1 hazardous locations. The C2 model allows general purpose enclosures, up to 10 cubic feet, to be used in certain Class 2 hazardous locations.\u003c\/p\u003e\u003cp\u003eDivision 1 areas must be surrounded by Division 2 areas.\u003c\/p\u003e\u003cp\u003eClass II, Group E areas must be rated as Division 1 areas.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200834085099,"sku":"648871","price":2718.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_A1001YZUMC1_Polycarbonate_regulator_handle.jpg?v=1786509345"},{"product_id":"hoffman-plcs1x1-purge-press-system-lk-comp-ext-mnt-type-x120vac-4-8-bar-60-cu-ft-ss316","title":"Hoffman PLCS1X1 | Purge Press. System, Lk Comp, Ext Mnt, Type X(120VAC), 4-8 bar, \u003c60 cu ft, SS316","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200835526891,"sku":"653803","price":17120.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PLCS1X1_Purge_Press_System.jpg?v=1786509375"},{"product_id":"hoffman-atpw60hgp-touch-up-paint-pen-hoffman-60-white","title":"Hoffman ATPW60HGP | Touch-Up Paint Pen, Hoffman #60 White","description":"\u003cp\u003eUse Touch-Up Paint Pen to repair the finish of enclosures and panels.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200836903147,"sku":"651033","price":27.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATPW60HGP_Touch-Up_Paint_Pen.jpg?v=1786509393"},{"product_id":"hoffman-atplga70-touch-up-paint-light-gray-ansi-70","title":"Hoffman ATPLGA70 | Touch-Up Paint, Light Gray ANSI 70","description":"\u003cp\u003eUse Touch-Up Paint to repair the color finish on enclosures and panels preventing corrosion and maintaining enclosure appearance.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200837886187,"sku":"651012","price":72.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATPLGA70_Touch-Up_Paint.jpg?v=1786509414"},{"product_id":"hoffman-atplg-touch-up-paint-light-gray-s052","title":"Hoffman ATPLG | Touch-Up Paint, Light Gray S052","description":"\u003cp\u003eUse Touch-Up Paint to repair the color finish on enclosures and panels preventing corrosion and maintaining enclosure appearance.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200837918955,"sku":"651011","price":72.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATPLG_Touch-Up_Paint.jpg?v=1786509413"},{"product_id":"hoffman-atpg7035-touch-up-paint-light-gray-ral-7035","title":"Hoffman ATPG7035 | Touch-Up Paint, Light Gray RAL 7035","description":"\u003cp\u003eUse Touch-Up Paint to repair the color finish on enclosures and panels preventing corrosion and maintaining enclosure appearance.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200837951723,"sku":"651006","price":41.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATPG7035_Touch-Up_Paint.jpg?v=1786509412"},{"product_id":"hoffman-p1224cn-cage-nut-package-12-24-steel-qty-20","title":"Hoffman P1224CN | Cage Nut Package, #12-24, Steel, Qty 20","description":"\u003cp\u003eThe Cage Nut Packages are for use with square-hole rack angles. They simply snap into the holes.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200840868075,"sku":"631244","price":89.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_P1224CN_Cage_Nut_Package.jpg?v=1786509474"},{"product_id":"hoffman-atpb7021-touch-up-paint-black-ral-7021","title":"Hoffman ATPB7021 | Touch-Up Paint, Black RAL 7021","description":"\u003cp\u003eUse Touch-Up Paint to repair the color finish on enclosures and panels preventing corrosion and maintaining enclosure appearance.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200843489515,"sku":"650994","price":43.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATPB7021_Touch-Up_Paint.jpg?v=1786509718"},{"product_id":"hoffman-abl-operator-adapter-for-universal-cutout-allen-bradley-large-handle","title":"Hoffman ABL | Operator Adapter for Universal Cutout, Allen Bradley, Large Handle","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200846569707,"sku":"650550","price":434.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ABL_Operator_Adapter.jpg?v=1786509737"},{"product_id":"hoffman-iw3000-ir-window-73x107x19mm","title":"Hoffman IW3000 | IR Window, 73x107x19mm","description":"\u003cp\u003eIR Windows provide a safe, efficient, and accurate way to perform electrical inspections or predictive maintenance without removing the panels or disturbing the electrical equipment. Installing the IR Windows can help protect employees from potential arc flash hazards and comply with NFPA70E safety guidelines. The special design and feature enable quicker inspections which save money and time. Made with durable broadband crystal optic and aluminum housing materials, IR Windows can be mounted to any enclosure. Equipped with HYDROGARD lens moisture protection, IR Windows can be installed both indoors and outdoors. IR Windows work with any thermal imager, expanding the application to many industries. Each kit comes with a self-adhesive drilling template, hardware, and step-by-step instructions for easy installation or can be preinstalled into HOFFMAN enclosures.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200863772907,"sku":"652868","price":424.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_IW3000_IR_Window.jpg?v=1786509869"},{"product_id":"hoffman-iw4000-ir-window-92x127x21mm","title":"Hoffman IW4000 | IR Window, 92x127x21mm","description":"\u003cp\u003eIR Windows provide a safe, efficient, and accurate way to perform electrical inspections or predictive maintenance without removing the panels or disturbing the electrical equipment. Installing the IR Windows can help protect employees from potential arc flash hazards and comply with NFPA70E safety guidelines. The special design and feature enable quicker inspections which save money and time. Made with durable broadband crystal optic and aluminum housing materials, IR Windows can be mounted to any enclosure. Equipped with HYDROGARD lens moisture protection, IR Windows can be installed both indoors and outdoors. IR Windows work with any thermal imager, expanding the application to many industries. Each kit comes with a self-adhesive drilling template, hardware, and step-by-step instructions for easy installation or can be preinstalled into HOFFMAN enclosures.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200863805675,"sku":"652869","price":696.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_IW3000_IR_Window_342136a0-bc9a-4265-82b2-d7155e53adbe.jpg?v=1786509869"},{"product_id":"hoffman-exebdm20ss6-hazardous-location-breather-drain-m20-ex-e-40x40x25mm-ss-type-316","title":"Hoffman EXEBDM20SS6 | Hazardous Location Breather Drain M20 Ex e, 40x40x25mm, SS Type 316","description":"\u003cp\u003eHazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200880025835,"sku":"652117","price":127.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_EXEBDM20SS6_Breather_Drain.jpg?v=1786509995"},{"product_id":"hoffman-exebdm25ss6-hazardous-location-breather-drains-m25-ex-e-40x40x25mm-ss-type-316","title":"Hoffman EXEBDM25SS6 | Hazardous Location Breather Drains, M25, Ex e, 40x40x25mm, SS Type 316","description":"\u003cp\u003eHazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200880058603,"sku":"652118","price":178.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_EXEBDM25SS6_Breather_Drains.jpg?v=1786509994"},{"product_id":"hoffman-exdbdm25ss6-hazardous-location-breather-drains-m25-ex-d-40x40x25mm-ss-type-316","title":"Hoffman EXDBDM25SS6 | Hazardous Location Breather Drains, M25, Ex d, 40x40x25mm, SS Type 316","description":"\u003cp\u003eHazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200881533163,"sku":"652076","price":414.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_EXDBDM25SS6_Breather_Drains.jpg?v=1786510001"},{"product_id":"hoffman-exdbdm20ss6-hazardous-location-breather-drains-m20-ex-d-40x40x25mm-ss-type-316","title":"Hoffman EXDBDM20SS6 | Hazardous Location Breather Drains, M20, Ex d, 40x40x25mm, SS Type 316","description":"\u003cp\u003eHazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200881991915,"sku":"652075","price":283.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_EXDBDM20SS6_Breather_Drains.jpg?v=1786510001"},{"product_id":"hoffman-echc-operator-adapter-for-universal-cutout-eaton-cutler-hammer-cable-operated","title":"Hoffman ECHC | Operator Adapter for Universal Cutout, Eaton Cutler Hammer, Cable Operated","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200888611051,"sku":"652040","price":434.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ECHC_Operator_Adapter.jpg?v=1786510057"},{"product_id":"hoffman-echv-operator-adapter-for-universal-cutout-eaton-cutler-hammer-variable-depth","title":"Hoffman ECHV | Operator Adapter for Universal Cutout, Eaton Cutler Hammer, Variable Depth","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200888643819,"sku":"652041","price":453.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ECHV_Operator_Adapter.jpg?v=1786510057"},{"product_id":"hoffman-a3456bap-blank-adapter-plates-mild-steel-fits-disc-cutout-gray-steel","title":"Hoffman A3456BAP | Blank Adapter Plates, Mild Steel, fits disc cutout, Gray, Steel","description":"\u003cp\u003eUsed to cover flange cutouts in disconnect enclosures when disconnects are not installed. This greatly increases the versatility of disconnect enclosures, enabling them to also be used as regular Type 12 enclosures. If the UBP model is used, the disconnect enclosure can be used as a regular Type 4 enclosure. HOFFMAN adapter plates are made from heavy gauge steel and have an oil-resistant gasket to maintain a dust-tight and oil-tight seal. Mounting hardware and instructions are included. Door hardware is not furnished with blank adapter plate. Door hardware must be ordered separately from the disconnect manufacturer when using catalog numbers A22BAP on Bulletin A22 Enclosures and A3456BAP on Bulletin A25 Enclosures.\u003c\/p\u003e\u003cp\u003eA22BAP will fit all Bulletin A22 enclosures except A48AB3812 and A60AB3812A2LP.\u003c\/p\u003e\u003cp\u003eA3456BA will fit all Bulletin A25 enclosures except A60SA3812A24LP.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200926621931,"sku":"649345","price":233.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_A3456BAP_Blank_Adapter_Plates.jpg?v=1786510242"},{"product_id":"hoffman-apcgetda-disconnect-operator-adapters-for-preferred-cutouts-for-ge-stda-steel","title":"Hoffman APCGETDA | Disconnect Operator Adapters for Preferred Cutouts, for GE STDA, Steel","description":"\u003cp\u003eAn operator adapter is required to install a disconnect in Bulletin A21S4, A28S4 and WS2D HOFFMAN enclosures that have a preferred cutout. Operator adapters include components needed to interlock the master door with the disconnect operating mechanism. Panel drilling and installation instructions are furnished with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the proper operator adapter and enclosure for the disconnect that you have selected.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200937959659,"sku":"650846","price":460.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_APCGETDA_Disconnect_Operator_Adapters.jpg?v=1786510327"},{"product_id":"hoffman-apcsda-disconnect-operator-adapters-for-preferred-cutouts-for-sq-d-9422-steel","title":"Hoffman APCSDA | Disconnect Operator Adapters for Preferred Cutouts, for Sq. D 9422, Steel","description":"\u003cp\u003eAn operator adapter is required to install a disconnect in Bulletin A21S4, A28S4 and WS2D HOFFMAN enclosures that have a preferred cutout. Operator adapters include components needed to interlock the master door with the disconnect operating mechanism. Panel drilling and installation instructions are furnished with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the proper operator adapter and enclosure for the disconnect that you have selected.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200937992427,"sku":"650848","price":460.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_APCSDA_Disconnect_Operator_Adapters.jpg?v=1786510327"},{"product_id":"hoffman-apcite-disconnect-operator-adapters-for-preferred-cutouts-for-i-t-e-max-flex-steel","title":"Hoffman APCITE | Disconnect Operator Adapters for Preferred Cutouts, for I-T-E Max-Flex, Steel","description":"\u003cp\u003eAn operator adapter is required to install a disconnect in Bulletin A21S4, A28S4 and WS2D HOFFMAN enclosures that have a preferred cutout. Operator adapters include components needed to interlock the master door with the disconnect operating mechanism. Panel drilling and installation instructions are furnished with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the proper operator adapter and enclosure for the disconnect that you have selected.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200938025195,"sku":"650847","price":460.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_APCITE_Disconnect_Operator_Adapters.jpg?v=1786510327"},{"product_id":"hoffman-apcabva-disconnect-operator-adapters-for-preferred-cutouts-for-a-b-1494v-steel","title":"Hoffman APCABVA | Disconnect Operator Adapters for Preferred Cutouts, for A-B 1494V, Steel","description":"\u003cp\u003eAn operator adapter is required to install a disconnect in Bulletin A21S4, A28S4 and WS2D HOFFMAN enclosures that have a preferred cutout. Operator adapters include components needed to interlock the master door with the disconnect operating mechanism. Panel drilling and installation instructions are furnished with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the proper operator adapter and enclosure for the disconnect that you have selected.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200938156267,"sku":"650842","price":460.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_APCABVA_Disconnect_Operator_Adapters.jpg?v=1786510327"},{"product_id":"hoffman-apcchva-disconnect-operator-adapters-for-preferred-cutouts-for-c-h-c361-c371-steel","title":"Hoffman APCCHVA | Disconnect Operator Adapters for Preferred Cutouts, for C-H C361\/C371, Steel","description":"\u003cp\u003eAn operator adapter is required to install a disconnect in Bulletin A21S4, A28S4 and WS2D HOFFMAN enclosures that have a preferred cutout. Operator adapters include components needed to interlock the master door with the disconnect operating mechanism. Panel drilling and installation instructions are furnished with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the proper operator adapter and enclosure for the disconnect that you have selected.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200938189035,"sku":"650843","price":460.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_APCCHVA_Disconnect_Operator_Adapters.jpg?v=1786510327"},{"product_id":"hoffman-ahk10324x-ul-recognized-hardware-kit-type-4x-10-32","title":"Hoffman AHK10324X | UL-Recognized Hardware Kit, Type 4X, 10-32","description":"\u003cp\u003eThese UL-recognized mountings kits are designed to maintain the overall UL Type rating of the enclosure when component mounting holes penetrate the exterior of the enclosure. These hardware kits are conveniently offered in three common fastener sizes to meet various applications.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200939368683,"sku":"650740","price":37.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHK10324X_UL-Recognized_Hardware_Kit.jpg?v=1786510340"},{"product_id":"hoffman-ahk14204x-ul-recognized-hardware-kit-type-4x-1-4-20","title":"Hoffman AHK14204X | UL-Recognized Hardware Kit, Type 4X, 1\/4-20","description":"\u003cp\u003eThese UL-recognized mountings kits are designed to maintain the overall UL Type rating of the enclosure when component mounting holes penetrate the exterior of the enclosure. These hardware kits are conveniently offered in three common fastener sizes to meet various applications.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200939401451,"sku":"650741","price":40.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHK14204X_UL-Recognized_Hardware_Kit.jpg?v=1786510340"},{"product_id":"hoffman-ahk38164x-ul-recognized-hardware-kit-type-4x-3-8-16","title":"Hoffman AHK38164X | UL-Recognized Hardware Kit, Type 4X, 3\/8-16","description":"\u003cp\u003eThese UL-recognized mountings kits are designed to maintain the overall UL Type rating of the enclosure when component mounting holes penetrate the exterior of the enclosure. These hardware kits are conveniently offered in three common fastener sizes to meet various applications.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200939466987,"sku":"650742","price":55.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHK38164X_UL-Recognized_Hardware_Kit.jpg?v=1786510340"},{"product_id":"hoffman-amod7218bap-barriers-72-12x18-12-steel","title":"Hoffman AMOD7218BAP | Barriers, 72.12x18.12, Steel","description":"\u003cp\u003eUsed to provide a barrier between individual enclosures in an assembly of modular enclosures. The flat plate is gasketed on both sides and inserted between two modular enclosures. Bolts and instructions are included.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200943071467,"sku":"650783","price":600.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AMOD7218BAP_Barriers.jpg?v=1786510362"},{"product_id":"hoffman-amod8418bap-barrier-84-12x18-12-steel","title":"Hoffman AMOD8418BAP | Barrier, 84.12x18.12, Steel","description":"\u003cp\u003eUsed to provide a barrier between individual enclosures in an assembly of modular enclosures. The flat plate is gasketed on both sides and inserted between two modular enclosures. Bolts and instructions are included.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200943399147,"sku":"650795","price":654.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AMOD8418BAP_Barrier.jpg?v=1786510363"},{"product_id":"hoffman-amod8424bap-barriers-84-12x24-12-steel","title":"Hoffman AMOD8424BAP | Barriers, 84.12x24.12, Steel","description":"\u003cp\u003eUsed to provide a barrier between individual enclosures in an assembly of modular enclosures. The flat plate is gasketed on both sides and inserted between two modular enclosures. Bolts and instructions are included.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200943595755,"sku":"650798","price":703.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AMOD8424BAP_Barriers.jpg?v=1786510371"},{"product_id":"hoffman-ahci60r-corrosion-inhibitor-roll-for-60-cu-ft-roll-package-qty-3","title":"Hoffman AHCI60R | Corrosion Inhibitor, Roll, for 60 cu.ft.\/roll, package qty 3","description":"\u003cp\u003eUse Corrosion Inhibitors to protect electronic components inside the enclosure against corrosion. It is simple and economical to use; no surface preparation is required and puts protected equipment to use immediately without degreasing or coating removal. Each inhibitor contains a special chemical combination that vaporizes and condenses on all surfaces in an enclosed area. Vapors will redeposit as needed in the event of condensation of moisture on surfaces. These vapors reach every part of an enclosure, protecting all interior components. They do not interfere with electrical, optical or mechanical surface properties. Protection is effective even in salt-water atmospheres. The AHCI5E and AHCI10E emitters have additional red-metal inhibitors for further protection. The normal useful life-span of Hoffman corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since Corrosion Inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors. Each Corrosion Inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). Hoffman corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e\u003cp\u003eThe normal useful life-span of HOFFMAN corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since HOFFMAN corrosion inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors.\u003c\/p\u003e\u003cp\u003eEach nVent HOFFMAN corrosion inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). HOFFMAN corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200944414955,"sku":"650738","price":232.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHCI60R_Corrosion_Inhibitor.jpg?v=1786510375"},{"product_id":"hoffman-ahci240r-corrosion-inhibitor-roll-for-240-cu-ft-roll-package-qty-1","title":"Hoffman AHCI240R | Corrosion Inhibitor, Roll, for 240 cu.ft.\/roll, package qty 1","description":"\u003cp\u003eUse Corrosion Inhibitors to protect electronic components inside the enclosure against corrosion. It is simple and economical to use; no surface preparation is required and puts protected equipment to use immediately without degreasing or coating removal. Each inhibitor contains a special chemical combination that vaporizes and condenses on all surfaces in an enclosed area. Vapors will redeposit as needed in the event of condensation of moisture on surfaces. These vapors reach every part of an enclosure, protecting all interior components. They do not interfere with electrical, optical or mechanical surface properties. Protection is effective even in salt-water atmospheres. The AHCI5E and AHCI10E emitters have additional red-metal inhibitors for further protection. The normal useful life-span of Hoffman corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since Corrosion Inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors. Each Corrosion Inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). Hoffman corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e\u003cp\u003eThe normal useful life-span of HOFFMAN corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since HOFFMAN corrosion inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors.\u003c\/p\u003e\u003cp\u003eEach nVent HOFFMAN corrosion inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). HOFFMAN corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200944447723,"sku":"650737","price":725.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHCI240R_Corrosion_Inhibitor.jpg?v=1786510375"},{"product_id":"hoffman-ahci1dv-corrosion-inhibitor-foam-1-cu-ft-package-quantity-50","title":"Hoffman AHCI1DV | Corrosion Inhibitor Foam, 1 cu.ft., package quantity 50","description":"\u003cp\u003eUse Corrosion Inhibitors to protect electronic components inside the enclosure against corrosion. It is simple and economical to use; no surface preparation is required and puts protected equipment to use immediately without degreasing or coating removal. Each inhibitor contains a special chemical combination that vaporizes and condenses on all surfaces in an enclosed area. Vapors will redeposit as needed in the event of condensation of moisture on surfaces. These vapors reach every part of an enclosure, protecting all interior components. They do not interfere with electrical, optical or mechanical surface properties. Protection is effective even in salt-water atmospheres. The AHCI5E and AHCI10E emitters have additional red-metal inhibitors for further protection. The normal useful life-span of Hoffman corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since Corrosion Inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors. Each Corrosion Inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). Hoffman corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e\u003cp\u003eThe normal useful life-span of HOFFMAN corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since HOFFMAN corrosion inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors.\u003c\/p\u003e\u003cp\u003eEach nVent HOFFMAN corrosion inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). HOFFMAN corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and\/or (3) cabinet length divided by depth is greater than four.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200944480491,"sku":"650736","price":13.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_AHCI1DV_Corrosion_Inhibitor_Foam.jpg?v=1786510375"},{"product_id":"hoffman-a1001yzumc2-small-volume-type-y-and-z-purging-pressurization-system-10cf-class-2","title":"Hoffman A1001YZUMC2 | Small-Volume Type Y and Z Purging\/Pressurization System, 10CF, Class 2","description":"\u003cp\u003eSmall-Volume Purging\/Pressurization Systems are an alternative to NEMA Type 7 or 9 enclosures. The C1 model allows general-purpose enclosures, up to two cubic feet, to be used in certain Class 1 hazardous locations. The C2 model allows general purpose enclosures, up to 10 cubic feet, to be used in certain Class 2 hazardous locations.\u003c\/p\u003e\u003cp\u003eDivision 1 areas must be surrounded by Division 2 areas.\u003c\/p\u003e\u003cp\u003eClass II, Group E areas must be rated as Division 1 areas.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200968040683,"sku":"648872","price":2718.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_A1001YZUMC2_Polycarbonate_regulator_handle.jpg?v=1786510554"},{"product_id":"hoffman-gev-operator-adapter-for-universal-cutout-general-electric-variable-depth","title":"Hoffman GEV | Operator Adapter for Universal Cutout, General Electric, Variable Depth","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200969744619,"sku":"652278","price":453.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_GEV_Operator_Adapter.jpg?v=1786510568"},{"product_id":"hoffman-gec-operator-adapter-for-universal-cutout-general-electric-cable-operated","title":"Hoffman GEC | Operator Adapter for Universal Cutout, General Electric, Cable Operated","description":"\u003cp\u003eUsed on all nVent HOFFMAN Type 4 and 12 disconnect enclosures with a universal flange cutout. An operator adapter is required to install a disconnect in Bulletin A21, A28, A34 and A4L3D HOFFMAN enclosures that have a universal cutout. Operator adapters include an adapter plate and additional components needed to interlock the master door with the disconnect operating mechanism. Installation instructions are included with each operator adapter. Each brand and type of disconnect requires a different operator adapter. Be sure to select the correct operator adapter and enclosure for the disconnect device selected. A 400A (or greater) disconnect switch and 600A (or greater) circuit breaker require the large handle. A 200A (or less) disconnect switch and 400A (or less) circuit breaker require a small handle.\u003c\/p\u003e\u003cp\u003ePlease use new catalog numbers when ordering. Refer to the spec sheet for a catalog number cross-reference.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200969777387,"sku":"652277","price":453.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_GEC_Operator_Adapter.jpg?v=1786510568"},{"product_id":"hoffman-gsm5-screw-package-steel","title":"Hoffman GSM5 | Screw Package, Steel","description":"\u003cp\u003eM5x10mm screws for Fusion G7 internal accessories.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200973742315,"sku":"652330","price":25.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_GSM5_Screw_Package.jpg?v=1786510598"},{"product_id":"hoffman-pcfskit-purge-and-pressurization-continuous-flow-service-kit","title":"Hoffman PCFSKIT | Purge and Pressurization Continuous Flow Service Kit","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200985243883,"sku":"653242","price":373.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PCFSKIT_Purge_and_Pressurization_Kit.jpg?v=1786510680"},{"product_id":"hoffman-pcfb1yz-purge-press-system-cont-flow-ext-mnt-type-y-z-4-8-bar-17-cu-ft-ss316","title":"Hoffman PCFB1YZ | Purge Press. System, Cont Flow, Ext Mnt, Type Y, Z, 4-8 bar, \u003c17 cu ft, SS316","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200985276651,"sku":"653240","price":3376.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PCFB1YZ_Purge_Press_System.jpg?v=1786510680"},{"product_id":"hoffman-pcff1yz-purge-press-system-cont-flow-flush-mnt-type-y-z-4-8-bar-17-cu-ft-ss316","title":"Hoffman PCFF1YZ | Purge Press. System, Cont Flow, Flush Mnt, Type Y, Z, 4-8 bar, \u003c17 cu ft, SS316","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200985309419,"sku":"653241","price":3376.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PCFF1YZ_Purge_Press_System.jpg?v=1786510680"},{"product_id":"hoffman-atrsdvr-tamper-resistant-screw-driver-bit","title":"Hoffman ATRSDVR | Tamper-Resistant Screw, Driver Bit","description":"\u003cp\u003eDesigned for field installation on screw cover pull boxes and screw cover Type 3R enclosures (size 16.00 x 12.00 x 6.00 in. or smaller), consolets, pushbutton enclosures and Type 12 screw cover wiring trough. Driver bit must be ordered separately.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200993304811,"sku":"651035","price":72.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATRSDVR_Tamper-Resistant_Screw.jpg?v=1786510742"},{"product_id":"hoffman-atrsk-tamper-resistant-screw-10-32-stainless-steel","title":"Hoffman ATRSK | Tamper-Resistant Screw, #10-32, Stainless Steel","description":"\u003cp\u003eDesigned for field installation on screw cover pull boxes and screw cover Type 3R enclosures (size 16.00 x 12.00 x 6.00 in. or smaller), consolets, pushbutton enclosures and Type 12 screw cover wiring trough. Driver bit must be ordered separately.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200993337579,"sku":"651036","price":27.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_ATRSK_Tamper-Resistant_Screw.jpg?v=1786510742"},{"product_id":"hoffman-plcs1x2-purge-press-system-lk-comp-ext-mnt-type-x230vac-4-8-bar-60-cu-ft-ss316","title":"Hoffman PLCS1X2 | Purge Press. System, Lk Comp, Ext Mnt, Type X(230VAC), 4-8 bar, \u003c60 cu ft, SS316","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200994287851,"sku":"653804","price":17805.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PLCS1X2_Purge_Press_System.jpg?v=1786510748"},{"product_id":"hoffman-plcskit-purge-and-pressurization-leak-compensation-service-kit","title":"Hoffman PLCSKIT | Purge and Pressurization Leak Compensation Service Kit","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200994320619,"sku":"653805","price":373.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PLCSKIT_Purge_and_Pressurization_Kit.jpg?v=1786510748"},{"product_id":"hoffman-plcb1yz-purge-press-system-lk-comp-ext-mnt-type-y-z-4-8-bar-60-cu-ft-ss316","title":"Hoffman PLCB1YZ | Purge Press. System, Lk Comp, Ext Mnt, Type Y, Z, 4-8 bar, \u003c60 cu ft, SS316","description":"\u003cp\u003ePurge and Pressurization is a protection method used with Type 4, 4X and 12 (IP54 recommended minimum) enclosures. The enclosure is initially purged to remove any internal explosive gases or dust. Once this is accomplished, the enclosure is pressurized with a protective air or inert gas supply. This provides a positive internal enclosure pressure which keeps any external explosive gases or dust from entering the enclosure. The two methods of purge and pressurization offered are Leak Compensation and Continuous Flow.\u003c\/p\u003e\u003cp\u003eLeak Compensation maintains positive pressure by compensating for losses. System consists of Control Unit and Relief Valve. Certification Type Y and Z models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less. Certification Type X Model: • Provides power disconnect when pressurization is lost or not attained • Provides automatic purge process • External mount • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 60 Ft3 or less.\u003c\/p\u003e\u003cp\u003eContinuous Flow provides positive pressure via continuous protective air flow through the enclosure. System consists of Control Unit, Calibrated Outlet Orifice and Relief Valve. Certification Type Y and Z Models: • Flush (internal) or external mount models • Local visual alarm indicator and dry contact output for remote alarm • Typically recommended for enclosures with volume of 17 Ft3 or less\u003c\/p\u003e\u003cp\u003eFor all IEC and ATEC applications, the final or complete integrated assembly must be submitted to a notified body for certification.\u003c\/p\u003e\u003cp\u003eSee Specification Sheet for Purge and Pressurization Systems and Certifications table.\u003c\/p\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49200994451691,"sku":"653801","price":4843.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Hoffman_PLCB1YZ_Purge_Press_System.jpg?v=1786510748"}],"url":"https:\/\/www.alldataresource.com\/collections\/other-accessories.oembed","provider":"All Data Resource","version":"1.0","type":"link"}