{"product_id":"altronix-t2ke33f16v-16-door-altronix-kisi-access-and-power-integration-kit-trove2lu2-with-2-eflow6nbv-2-acm8","title":"Altronix T2KE33F16V | 16-Door Altronix\/Kisi Access and Power Integration Kit - Trove2LU2 with (2) eFlow6NBV, (2) ACM8","description":"Altronix T2KE33F16V | 16-Door Altronix\/Kisi Access and Power Integration Kit - Trove2LU2 with (2) eFlow6NBV, (2) ACM8\u003cbr\u003e\u003cbr\u003e\u003ch5\u003eTwo (2) eFlow6NBV Power Supply\/Chargers \/ Input\u003c\/h5\u003eVoltage: 220VAC (working range 198VAC - 256VAC), 50\/60Hz, 2.5A.\u003cbr\u003eMain Fuse: 5A \/ 250V.\u003ch5\u003eOutput\u003c\/h5\u003eVoltage: 12VDC or 24VDC selectable.\u003cbr\u003eCurrent: 6A continuous max.\u003cbr\u003eAuxiliary: Power-limited @ 1A (unswitched)\u003cbr\u003eOther: Overvoltage protection. Filtered and regulated.\u003ch5\u003eBattery Backup\u003c\/h5\u003eCapacity: 12AH\/12VDC (Up to 4 within enclosure) 40AH\/65AH (requires separate enclosure).\u003cbr\u003eType: Sealed lead acid or gel type.\u003cbr\u003eFuse Rating: 10A @ 32V.\u003cbr\u003eFailover: Upon AC loss, instantaneous.\u003ch5\u003eFire Alarm Disconnect\u003c\/h5\u003eSupervised: Latching or non-latching.\u003cbr\u003eEOL: 10K Resistor.\u003ch5\u003eSupervision\u003c\/h5\u003eAC Failure: Form “C” contacts.\u003cbr\u003eBattery: Form “C” contacts.\u003cbr\u003eLow DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.\u003ch5\u003eIndicators LED\u003c\/h5\u003eInput: 220VAC is present.\u003cbr\u003eDC Output: Powered.\u003ch5\u003eTwo (2) ACM8 Access Power Controllers \/ Input\u003c\/h5\u003eVoltage: 24VDC from eFlow6NBV.\u003cbr\u003eMain Fuse: 10A \/ 250V.\u003ch5\u003eOutputs\u003c\/h5\u003eVoltage: 24VDC.\u003cbr\u003eEight (8) independently controlled fused outputs:\u003cbr\u003ea) Fail-Safe and\/or Fail-Secure power outputs.\u003cbr\u003eForm “C” Relays rated 28VAC or VDC @ 2.5A.\u003cbr\u003eb) Auxiliary power outputs (unswitched).\u003cbr\u003ec) Any combination of the above.\u003cbr\u003eOutput Fuses: 3.5A \/ 250V.\u003ch5\u003eIndicators (LED)\u003c\/h5\u003eRed LEDs: Outputs are triggered (relays energized).\u003cbr\u003eGreen LED: FACP disconnect is triggered.\u003ch5\u003eEnvironmental \/ Temperature\u003c\/h5\u003eOperating: 0° C to 49° C (32° F to 120° F).\u003cbr\u003eStorage: - 20° C to 70° C ( - 4° F to 158° F).\u003ch5\u003eRelative Humidity\u003c\/h5\u003eRelative Humidity 85% +\/- 5%.\u003ch5\u003eBTU\/Hr (approx.):\u003c\/h5\u003e12VDC: 74 BTU\/Hr.\u003cbr\u003e24VDC: 148 BTU\/Hr.\u003cbr\u003e12VDC and 24VDC: 111 BTU\/Hr.","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49212943597803,"sku":"10265926","price":1534.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/Altronix-T2KE33F16V-Trove2-Altx-Kisi-16Dr-Fuse-220-Main2.jpg?v=1786585684","url":"https:\/\/www.alldataresource.com\/products\/altronix-t2ke33f16v-16-door-altronix-kisi-access-and-power-integration-kit-trove2lu2-with-2-eflow6nbv-2-acm8","provider":"All Data Resource","version":"1.0","type":"link"}