{"product_id":"panduit-fsc2mcxaq-fiber-optic-connectors-sc2-opticam-upc-61305625636","title":"Panduit FSC2MCXAQ | Fiber Optic Connectors, SC2 OptiCam | UPC - 61305625636","description":"\u003cp\u003e\nPanduit Fiber Optic Connector, SC2 Simplex Connector, 50\/125 um OM3\/OM4 Multi-Mode Fiber, 900 um Buffered Cable, Zirconia Ceramic Ferrule, Aqua\n\u003c\/p\u003e\n\u003ch3\u003eFeatures + Benefits\u003c\/h3\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eFactory pre-polished fiber stub end face eliminates inconsistent and time consuming field polishing to deliver required optical performance\u003c\/li\u003e\n\u003cli\u003eDual cam design with fiber and buffer clamps secures both the fiber and the buffer during the camming step to facilitate consistent termination results, reduces the termination time compared to conventional termination methods\u003c\/li\u003e\n\u003cli\u003eAllows up to two re-terminations to achieve optimum termination results, reduces the number of rejected connectors and terminations to provide yield rates approaching 100% for lower installed costs\u003c\/li\u003e\n\u003cli\u003eTranslucent inner housing assembly facilitates inspection of the fiber termination quality, results in rapid installations, improved termination yields and lower installed costs\u003c\/li\u003e\n\u003cli\u003eMechanical cable retention consistently provides higher than industry standard cable retention, requires no adhesive, speeding installation\u003c\/li\u003e\n\u003cli\u003eReduces termination time (less than half the time of field polish connectors) and the number of installation tools required\u003c\/li\u003e\n\u003cli\u003eNon-optical disconnect design maintains data transmission under tensile loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\u003ch3\u003e\u003cstrong\u003ePanduit FSC2MCXAQ Key Specs \u003c\/strong\u003e\u003c\/h3\u003e\u003cbr\u003e\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 800px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eFor use with the OptiCam 2 Termination Tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003ePolish Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003ePre-Polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eOM3\/OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eSub Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eOptiCam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eMaintenance or emergency restoration of fiber networks and retrofit\/initial install in both behind-the-wall (BTW) and in the permanent side of panelized interconnect and cross-connect.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eBody Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eAqua\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eBoot Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eAqua\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eBackbone Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eFiber Diameter (µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Operating Temperature (°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Operating Temperature (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Operating Temperature (°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMinimum Operating Temperature (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eStandards Met\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eRoHS Compliant; TIA\/EIA-604 FOCIS-3 compliant; exceeds TIA\/EIA-568-D.3 requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eFiber Optic Connectors, SC2 OptiCam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"clear: both; padding-top: 3px\"\u003e\n\u003chr\u003e\n\u003ch3\u003e Panduit FSC2MCXAQ Data Sheets \u003c\/h3\u003e\n\u003cbr\u003e\u003cdiv style=\"align-items: center; display: flex;\"\u003e\n\u003cdiv style=\"float: left; height: 46px; width: 47px; padding-right: 3px;\"\u003e\u003cimg alt=\"Downloads\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/pdfdownload2.png?v=1786520581\" style=\"width: 100%; height: 46px;\"\u003e\u003c\/div\u003e\n\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 750px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border: 1px #d5d5d5; border-collapse: collapse;background-color: #f5f5f5; \"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eInstallation Documents | Wyr-Grid 2 Post Channel Trapeze Rack Mount Brackets: RW299\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/98404670.pdf?v=1786758337\" target=\"_blank\" title=\"Installation Documents | Wyr-Grid 2 Post Channel Trapeze Rack Mount Brackets: RW299\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\" border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003ePart Drawings | Wyr-Grid Rack Mount Bracket for 12\" Wide Pathways - WG2PRB12BL\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/98404676.pdf?v=1787048335\" pathways=\"\" target=\"_blank\" title=\"Part Drawings | Wyr-Grid Rack Mount Bracket for 12\" wg2prb12bl wide=\"\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border: 1px #d5d5d5; border-collapse: collapse;background-color: #f5f5f5; \"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eTechnical References | Wyr-Grid Cable Tray Load Rating Report: FRTR01--WW-ENG\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/98580781.pdf?v=1786758338\" target=\"_blank\" title=\"Technical References | Wyr-Grid Cable Tray Load Rating Report: FRTR01--WW-ENG\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both; padding-top: 3px\"\u003e\n\u003chr\u003e\n\u003ch3\u003e Panduit FSC2MCXAQ Environmental Information \u003c\/h3\u003e\n\u003cdiv style=\"align-items: center; display: flex;\"\u003e\n\u003cdiv style=\"float: left; height: 39px; width: 72px ; padding-right: 3px;\"\u003e\u003cimg alt=\"Environmental Information\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/RoHS_20image.jpg?v=1786520581\" style=\"width:100%; \"\u003e\u003c\/div\u003e\n\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 725px;\"\u003e\u003ctbody\u003e\u003ctr style=\"border: 1px #d5d5d5; border-collapse: collapse;background-color: #f5f5f5;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e\u003cstrong\u003ePanduit's RoHS Statement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/RoHS-Panduit.pdf?v=1786758339\" target=\"_blank\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Anixter","offers":[{"title":"Default Title","offer_id":49202797969643,"sku":"909965","price":23.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/54850836.jpg?v=1786524305","url":"https:\/\/www.alldataresource.com\/products\/panduit-fsc2mcxaq-fiber-optic-connectors-sc2-opticam-upc-61305625636","provider":"All Data Resource","version":"1.0","type":"link"}