{"product_id":"panduit-p14-6lf-m-loose-piece-forks-upc-07498380907","title":"Panduit P14-6LF-M | Loose Piece Forks | UPC - 07498380907","description":"\u003cp\u003e\nPanduit Pan-Term Fork Terminal, Loose Piece Non-Insulated, Series: P-LF, Stranded Copper Conductor, 18 to 14 AWG Conductor, #6 Stud, 0.7 in Length, Brazed Seam Barrel, 0.09 in ID x 0.16 in OD Barrel, Locking Fork Tongue, 0.25 in W x 0.03 in THK Tongue, 2000 VAC, 9\/32 in L Wire Strip, 0.22 in Clearance, Standard Barrel Configuration, 302 deg F, Copper, Tin Plated, Metallic\n\u003c\/p\u003e\n\u003ch3\u003eFeatures + Benefits\u003c\/h3\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eExpanded wire entry designed to accommodate wire with a larger insulation thickness\u003c\/li\u003e\n\u003cli\u003eFork design provides for fast and easy installation, without the need to remove fastener\u003c\/li\u003e\n\u003cli\u003eInsulation support helps to prevent wire damage in bending applications\u003c\/li\u003e\n\u003cli\u003eBrazed seam protects terminal barrel from splitting during the crimp process\u003c\/li\u003e\n\u003cli\u003eInternal barrel serrations assure good wire contact and maximum tensile strength\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\u003ch3\u003e\u003cstrong\u003ePanduit P14-6LF-M | Loose Piece Forks | UPC - 07498380907 Key Specs \u003c\/strong\u003e\u003c\/h3\u003e\u003cbr\u003e\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 800px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eFork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eLocking Fork\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eInsulation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eNon-Insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Copper Conductor Size (AWG SOL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Copper Conductor Size (AWG STR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Copper Conductor Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Wire Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMinimum Wire Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Copper Conductor Size (AWG SOL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMinimum Copper Conductor Size (AWG STR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Copper Conductor Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Metric Conductor Size (mm²)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Metric Conductor Size (mm²)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eStud Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eWire Strip Length (In.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e0.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eWire Strip Length (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e7.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eStandards Met\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eUL Listed 587H E52164; CSA Certified LR31212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Voltage (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Voltage (kV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eBase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"clear: both; padding-top: 3px\"\u003e\n\u003chr\u003e\n\u003ch3\u003e Panduit P14-6LF-M | Loose Piece Forks | UPC - 07498380907 Data Sheets \u003c\/h3\u003e\n\u003cbr\u003e\u003cdiv style=\"align-items: center; display: flex;\"\u003e\n\u003cdiv style=\"float: left; height: 46px; width: 47px; padding-right: 3px;\"\u003e\u003cimg alt=\"Downloads\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/pdfdownload2.png?v=1786520581\" style=\"width: 100%; height: 46px;\"\u003e\u003c\/div\u003e\n\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 750px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border: 1px #d5d5d5; border-collapse: collapse;background-color: #f5f5f5; \"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eSelection Guides | Terminal Tools Selection Guide\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/100866606.pdf?v=1786758326\" target=\"_blank\" title=\"Selection Guides | Terminal Tools Selection Guide\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\" border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003ePart Drawings | #18-14 Barrel Non-Insulated Locking Fork\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/28927.pdf?v=1786758334\" target=\"_blank\" title=\"Part Drawings | #18-14 Barrel Non-Insulated Locking Fork\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both; padding-top: 3px\"\u003e\n\u003chr\u003e\n\u003ch3\u003e Panduit P14-6LF-M | Loose Piece Forks | UPC - 07498380907 Environmental Information \u003c\/h3\u003e\n\u003cdiv style=\"align-items: center; display: flex;\"\u003e\n\u003cdiv style=\"float: left; height: 39px; width: 72px ; padding-right: 3px;\"\u003e\u003cimg alt=\"Environmental Information\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/RoHS_20image.jpg?v=1786520581\" style=\"width:100%; \"\u003e\u003c\/div\u003e\n\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 725px;\"\u003e\u003ctbody\u003e\u003ctr style=\"border: 1px #d5d5d5; border-collapse: collapse;background-color: #f5f5f5;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e\u003cstrong\u003ePanduit's RoHS Statement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/RoHS-Panduit.pdf?v=1786758339\" target=\"_blank\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Panduit","offers":[{"title":"Default Title","offer_id":49202767200491,"sku":"PAN-P14-6LF-M","price":220.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/306640_784e167f-ce76-415b-aa07-461c414d8771.jpg?v=1786524119","url":"https:\/\/www.alldataresource.com\/products\/panduit-p14-6lf-m-loose-piece-forks-upc-07498380907","provider":"All Data Resource","version":"1.0","type":"link"}