{"product_id":"panduit-pv18-6ff-cy-loose-piece-terminal-upc-07498369177","title":"Panduit PV18-6FF-CY | Loose Piece Terminal | UPC - 07498369177","description":"\u003cp\u003e\nPanduit Pan-Term Fork Terminal, Loose Piece, Series: PV-FF, Stranded Copper Conductor, 22 to 16 AWG Conductor, #6 Stud, 0.87 in Length, Brazed Seam\/Funnel Entry Barrel, Flanged Fork Tongue, 0.28 in W x 0.032 in THK Tongue, 600 VAC, 5\/16 in L Wire Strip, 0.15 in Dia Vinyl Insulation, 0.19 in Clearance, 221 deg F, Copper, Tin Plated, Red\n\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType TN-F, nylon insulated fork tongue terminal has the same high quality as the TN\u003c\/li\u003e\n\u003cli\u003eIt is designed to meet the heavy duty requirements of industrial and utility applications\u003c\/li\u003e\n\u003cli\u003eTN-F provides high dielectric strength and stability in oily conditions\u003c\/li\u003e\n\u003cli\u003eFork tongue provides faster and easier installation by permitting insertion under the screw head without completely removing it\u003c\/li\u003e\n\u003cli\u003eFor Y10D, Y10-22 non-ratchet hand crimper plier and MRE1022NV, MR8-83, MR18 ratchet crimper\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\u003ch3\u003e\u003cstrong\u003ePanduit Panduit PV18-6FF-CY | Loose Piece Terminal | UPC - 07498369177 Key Specs \u003c\/strong\u003e\u003c\/h3\u003e\u003cbr\u003e\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 800px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003ePV18-6FF-CY replaces PV18-6FF-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eFork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eFlanged Fork\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003eVinyl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eInsulation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eVinyl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Copper Conductor Size (AWG SOL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Copper Conductor Size (AWG STR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Copper Conductor Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Wire Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMinimum Wire Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Copper Conductor Size (AWG SOL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMinimum Copper Conductor Size (AWG STR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Copper Conductor Size (AWG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e#22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Metric Conductor Size (mm²)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMinimum Metric Conductor Size (mm²)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eStud Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e#6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eWire Strip Length (In.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e0.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eWire Strip Length (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e7.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eStandards Met\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003eCSA certified C22.2 No.65,UL Listed UL486A-486B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f5f5; border: 1px #d5d5d5; border-collapse: collapse;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px;\"\u003e\u003cstrong\u003eMaximum Voltage (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px\"\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; width: 400px\"\u003e\u003cstrong\u003eMaximum Voltage (kV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"clear: both; padding-top: 3px\"\u003e\n\u003chr\u003e\n\u003ch3\u003e Panduit Panduit PV18-6FF-CY | Loose Piece Terminal | UPC - 07498369177 Environmental Information \u003c\/h3\u003e\n\u003cbr\u003e\u003cdiv style=\"align-items: center; display: flex;\"\u003e\n\u003cdiv style=\"float: left; height: 39px; width: 72px ; padding-right: 3px;\"\u003e\u003cimg alt=\"Environmental Information\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/RoHS_20image.jpg?v=1786520581\" style=\"width:100%; \"\u003e\u003c\/div\u003e\n\u003ctable style=\"border-spacing: 0px; border: 1px rgb(213, 213, 213); border-collapse: collapse; float: left; width: 725px;\"\u003e\u003ctbody\u003e\u003ctr style=\"border: 1px #d5d5d5; border-collapse: collapse;background-color: #f5f5f5;\"\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px;\"\u003e\u003cstrong\u003ePanduit's RoHS Statement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-collapse: collapse; border: 1px solid #d5d5d5; padding: 8px; text-align: center; width:200px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/RoHS-Panduit.pdf?v=1786758339\" target=\"_blank\"\u003e\u003cstrong\u003eDownload and View\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Panduit","offers":[{"title":"Default Title","offer_id":49202630459627,"sku":"10044860","price":99.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0843\/1616\/0235\/files\/311008_d4085206-f127-4650-b349-a30794bd955d.jpg?v=1786523103","url":"https:\/\/www.alldataresource.com\/products\/panduit-pv18-6ff-cy-loose-piece-terminal-upc-07498369177","provider":"All Data Resource","version":"1.0","type":"link"}