Brand: Altronix
|
SKU:
10022328
Altronix MAXIMAL75V | Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, 1 P/S 24VDC @ 9.7A & 1 P/S 12VDC @ 9.5A, 220VAC, BC800 Enclosure
Regular price
$1,250.75
Unit price
Shipping calculated at checkout.
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Description
Description
Altronix MAXIMAL75V | Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, 1 P/S 24VDC @ 9.7A & 1 P/S 12VDC @ 9.5A, 220VAC, BC800 Enclosure
b) Two (2) isolated power inputs (external power supply is required), (current is determined by thepower supply connected, not to exceed a maximum of 10A total).
Sixteen (16) Access Control System trigger inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
Sixteen (16) independently controlled outputs.
b) Sixteen (16) form "C" 5A rated relay outputs.
c) Any combination of the above.
Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5A).
Filtered and electronically regulated outputs (built-in power supply).
Thermal and short circuit protection with auto reset.
AL1012XB220 - 5A/250V
Power Supply output fuse ratings: AL1024XB2V/AL1012XB220 - 15A/32V
ACM8 boards main fuse is rated at 10A, Output fuses are rated @ 3.5A.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery and battery presence supervision (form "C" contact).
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).
Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.): 177 BTU/Hr.
System AC input VA requirement: 814VA.
Input
220VAC (working range 198VAC - 256VAC), 50/60Hz, 3.7A input.Power supply input options:
a) Two (2) common power input for either ACM8 and lock power (factory installed).b) Two (2) isolated power inputs (external power supply is required), (current is determined by thepower supply connected, not to exceed a maximum of 10A total).
Sixteen (16) Access Control System trigger inputs.
Input options:
a) Sixteen (16) normally open (NO) inputs.b) Sixteen (16) open collector inputs.
c) Any combination of the above.
Output
12VDC and 24VDC outputs.Maximum output current Options:
A) 24VDC @ 9.7A plus 12VDC @ 9.5A.Sixteen (16) independently controlled outputs.
Output options:
a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.b) Sixteen (16) form "C" 5A rated relay outputs.
c) Any combination of the above.
Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5A).
Filtered and electronically regulated outputs (built-in power supply).
Thermal and short circuit protection with auto reset.
Fuse Ratings / Power Supply input fuse ratings:
AL1024XB2V - 5A/250VAL1012XB220 - 5A/250V
Power Supply output fuse ratings: AL1024XB2V/AL1012XB220 - 15A/32V
ACM8 boards main fuse is rated at 10A, Output fuses are rated @ 3.5A.
Features
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
Supervision
AC fail supervision (form "C" contacts).Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery and battery presence supervision (form "C" contact).
Battery Backup
Built-in charger for sealed lead acid or gel type batteries.Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).
Visual Indicators
Red LEDs indicate outputs are triggered (relays energized).Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Electrical / Temperature:
Operating: 0° C to 49° C (32° F to 120° F).Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.): 177 BTU/Hr.
System AC input VA requirement: 814VA.
Overview
- Maximal75V distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC and 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.
Specifications
Specifications
Altronix - MAXIMAL75V - Overview
- Maximal75V distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC and 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.
Altronix - MAXIMAL75V - Product Categories
- Security
- Access Control
- Power Supplies
Altronix - MAXIMAL75V - Specifications
| Brand Name | Altronix |
|---|---|
| Manufacturer Part Number | MAXIMAL75V |
| Item Description | Access Power Controller w/ Power Supply/Chargers, 16 Fused Relay Outputs, 1 P/S 24VDC @ 9.7A & 1 P/S 12VDC @ 9.5A, 220VAC, BC800 Enclosure |
| Agency Listings | CE Compliant |
| Amps | 5.1 To 10.0 |
| Input Voltage | 120V Ac |
| Battery Charging | Battery Charging Circuit |
| Product Type | Boxed Power Supply |
| Battery Type Req | Sealed Lead Acid Or Gel |
| Sales Category | Power Supply |
| Fire Alarm Zones | 1 |
| Output Voltage | Selectable 12 Or 24 Volts Dc |
| Ul Listing | Ul Listed |
| UNSPSC Code | 43211700 |
| Weights (approximate): | - |
| Product Weight: | 43.7 Lbs. |
| (19.82 kg). | Shipping Weight: |
| 47.7 Lbs. | (21.64 kg). |
Documents and Downloads
Documents and Downloads
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.