Brand: Altronix
|
SKU:
10386441
Altronix T2IRK78SD | 8-Door Altronix/Inner Range Access and Power Integration Kit - Trove2IR2 with AL1024ULXB2, ACMS8CB, VR6, PDS8CB
Regular price
$1,408.68
Unit price
Shipping calculated at checkout.
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Description
Description
Altronix T2IRK78SD | 8-Door Altronix/Inner Range Access and Power Integration Kit - Trove2IR2 with AL1024ULXB2, ACMS8CB, VR6, PDS8CB
Main Fuse: 5A / 250V.
Current: 10A @ 24VDC continuous max.
Other: Overvoltage protection. Filtered and regulated.
Type: Sealed lead acid or gel type.
Failover: Upon AC loss, instantaneous.
Battery: Form “C” contacts.
DC Output: Powered.
Battery: Discharged or not connected.
Current: 6A continuous.
Other: Surge suppression.
Output: Powered.
Input PTC: 9A.
Eight (8) 24VDC independently controlled PTC outputs:
a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Auxiliary power outputs (unswitched).
c) Any combination of the above.
Green LED: FACP disconnect is triggered.
Input PTC: 9A.
Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Green: 12VDC
Red: 24VDC.
Storage: - 20° C to 70° C ( - 4° F to 158° F).
AL1024ULXB2 Power Supply/Charger / Input
Voltage: 115VAC 60Hz, 4.2A max.Main Fuse: 5A / 250V.
Outputs
Voltage: 24VDC.Current: 10A @ 24VDC continuous max.
Other: Overvoltage protection. Filtered and regulated.
Battery Backup
Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure).Type: Sealed lead acid or gel type.
Failover: Upon AC loss, instantaneous.
Supervision
AC Failure: Form “C” contacts.Battery: Form “C” contacts.
Indicators LED
Input: 115VAC is present.DC Output: Powered.
Battery: Discharged or not connected.
VR6 Voltage Regulator / Input
Voltage: 24VDC from AL1024ULXB2.Output
Voltage: 12VDC.Current: 6A continuous.
Other: Surge suppression.
Indicators LED
Input: 24VDC is present.Output: Powered.
ACMS8CB Dual Input Access Power Controller / Input
Voltage: 24VDC from AL1024ULXB2.Input PTC: 9A.
Outputs
Voltage: 24VDC.Eight (8) 24VDC independently controlled PTC outputs:
a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Auxiliary power outputs (unswitched).
c) Any combination of the above.
Outputs Ratings
PTCs: 2.5A.Indicators (LED)
Red LEDs: Outputs are triggered (relays energized).Green LED: FACP disconnect is triggered.
PDS8CB Dual Input Power Distribution Module / Input
Voltage: 12VDC from VR6 and 24VDC from AL1024ULXB2.Input PTC: 9A.
Outputs
Voltage: 12VDC and/or 24VDC.Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Outputs Ratings
PTCs: 2.5A.Indicators (LED)
DC Output: Eight (8) individual output LEDs.Green: 12VDC
Red: 24VDC.
Environmental / Temperature
Operating: 0° C to 50° C (32° F to 120° F).Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
Relative Humidity 85% +/- 5%.BTU/Hr (approx.):
131 BTU/Hr.Overview
- Altronix T2IRK78SD kit consists of Trove2 enclosure, TIR2 Inner Range/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 8-output PTC access power controller, one (1) voltage regulator and one (1) dual input PTC power distribution module. This kit also accommodate the following Integriti modules one (1) Security Controller or one (1) Access Controller module and five (5) Integriti Intelligent LAN Access modules or five (5) Integriti Standard LAN Access modules or five (5) Integriti 8-32 Zone LAN I/O Expander Modules or six (6) Standard LAN Access Modules or six (6) 8 Zone Expansion Device or six (6) Unibus 8 Relay Expander modules or six (6) Unibus 8 Relay Auxiliary Expander modules a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Specifications
Specifications
Altronix - T2IRK78SD - Overview
- Altronix T2IRK78SD kit consists of Trove2 enclosure, TIR2 Inner Range/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 8-output PTC access power controller, one (1) voltage regulator and one (1) dual input PTC power distribution module. This kit also accommodate the following Integriti modules one (1) Security Controller or one (1) Access Controller module and five (5) Integriti Intelligent LAN Access modules or five (5) Integriti Standard LAN Access modules or five (5) Integriti 8-32 Zone LAN I/O Expander Modules or six (6) Standard LAN Access Modules or six (6) 8 Zone Expansion Device or six (6) Unibus 8 Relay Expander modules or six (6) Unibus 8 Relay Auxiliary Expander modules a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Altronix - T2IRK78SD - Product Categories
- Security
- Access Control
- Panels
Altronix - T2IRK78SD - Specifications
| Brand Name | Altronix |
|---|---|
| Manufacturer Part Number | T2IRK78SD |
| Item Description | 8-Door Altronix/Inner Range Access and Power Integration Kit - Trove2IR2 with AL1024ULXB2, ACMS8CB, VR6, PDS8CB |
| Agency Listings | CE Compliant |
| Number Of Readers | 8 |
| UNSPSC Code | 43211700 |
| Weights (approximate): | - |
| Product Weight: | 54.6 Lbs. |
| (24.8 kg). | Shipping Weight: |
| 59.6 Lbs. | (27 kg). |
Documents and Downloads
Documents and Downloads
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
