Mircom Technologies MR-400RP | Addressable Fire Alarm Control Panel
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Description
Description
The MR-400 Fire Alarm Control Panel is an addressable panel, ideal for small to medium jobs. The MR-400 is shipped pre-assembled with main board, power supply, transformer, main display, black backbox, and red door enclosure. Compatible with Secutron addressable devices (MRI-4000 Series), the MR-400 comes with one addressable (SLC) loop with a maximum of 240 Secutron addressable devices in total. The MR-400 is equipped with a built-in POTs dialer. The dialer provides a means to communicate panel status to the remote central monitoring station using two dedicated phone lines.
Mircom Technologies, Ltd. - MR-400RP - Features
- Main Board, Power Supply and Backbox.
- Flexible zone and group configuration options.
- 4 x 20 Main LCD Display.
- Password Protection – no key is required.
- Class A, Class X, or Class B analog loop(s).
- Four Power Limited Class B, Class A NAC circuits (max 1.5 Amps each – 5.0 Amps total).
- One addressable (SLC) loop with a maximum of 240 Secutron devices (MRI-4000 series) in total.
- Dedicated common alarm, supervisory, trouble, and auxiliary alarm relays.
- Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised, 24VDC filtered and regulated, and resettable auxiliary power supply.
- Built-in POTs dialer which allows for the reporting of events to a monitoring facility.
Specifications
Specifications
Mircom Technologies, Ltd. - MR-400RP - Specifications
| AC Input | 120VAC @ 60Hz / 240VAC @ 50Hz |
|---|---|
| Charging Capability | 10AH to 24AH |
| Current Consumption | Standby 50mA / Alarm 300mA (city tie in use) / Alarm 70mA (city tie not in use) |
| Appliance Circuits | Power limited / Regulated 24V FWR / 1.5A @ 49C per circuit / Max power allowed Total 5.0A 1.5A per circuit |
| Aux supply 1 | Power limited / 24VDC regulated / 500mA max |
| Aux supply 2 | Resettable Power limited / 24VDC regulated / 300mA max |
| Unfiltered supply | Power limited / 24V FWR special application / 1.7A max at 49C |
| Auxiliary relays | Common Alarm/Supv./Trouble/ Auxiliary Alarm / Must be connected to a listed power limited source of supply Form C/28VDC/1A max |