Mircom Technologies MR-401RP | Addressable Fire Alarm Controlpanel, 3 (slc) Loops, Multi-zoned For Mri-4000
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Description
Description
The MR-401 Addressable Fire Alarm Control Panel is a 3 (SLC) loops addressable multi-zoned panel compatible with the new MRI-4000 Series.
Mircom Technologies, Ltd. - MR-401RP - Features
- Main Board, Power Supply and Backbox.
- Flexible zone and group configuration options.
- 3500 Main Display with 4 x 20 LCD display.
- Class A (DCLA), Class X (DCLC), or Class B (DCLB) analog loop(s).
- Four Power Limited Class B, Class A NAC circuits (max 1.5 Amps each – 6.0 Amps total).
- Up to 3 MRI-4000 Compatible (SLC) loops with a maximum of 720 devices, 240 per loop.
- Dedicated common alarm, supervisory, trouble, and auxiliary alarm relays.
- Additional RAX-1048TZDS Display Adder Module can be added to provide 96 annunciation points per Adder.
- Additional outputs include connections for a remote trouble indicator MR-2300T, Reverse Polarity Module MR-2300-PR, an RS-485 bus for connection of up to seven RAX-LCD-LITE, RAM-3500-LCDs, SRM-312s and RA-1000 Series annunciators.
- Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised, 24VDC filtered and regulated, and resettable auxiliary power supply.
- Built-in POTs dialer which allows for the reporting of events to a monitoring facility.
Specifications
Specifications
Mircom Technologies, Ltd. - MR-401RP - Specifications
| AC Input | 120VAC @ 60Hz / 240VAC @ 50Hz |
|---|---|
| Charging Capability | 10AH to 42AH |
| Current Consumption | Standby 50mA / Alarm 300mA (city tie in use) / Aalarm 70mA (city tie not in use) |
| Notification Appliance Circuits | Power limited / Regulated 24V FWR / 1.5A @ 49C per circuit / Max power allowed Total 6.0A |
| Aux supply 1 | Power limited / 24VDC regulated / 500mA max |
| Aux supply 2 | Resettable Power limited / 24VDC regulated / 300mA max |
| Unfiltered supply | Power limited / 24V FWR special application / 1.7A max at 49C |
| Auxiliary relays | Common Alarm/Supv./Trouble/ Auxiliary Alarm / Must be connected to a listed power limited source of supply Form C/28VDC/1A max |