Description
Description
NetKey 2-fiber OS2 SC duplex to SC duplex patch cord, low smoke zero halogen (LSZH) rated with 3.0mm jacket.
NKFP923LSSSM015 NetKey 2-fiber OS2 SC duplex to SC duplex patch cord low smoke zero halogen (LSZH) rated with 3.0mm jacket.
Panduit - NKFP923LSSSM015 - Features
- Provide electrical continuity to Panduit Wyr-Grid system and most industry standard ladder rack eliminate the need to remove paint and drill holes for grounding jumpers, saving labor
- Maintains a 2 in distance from grounding conductors and other cables in the pathway
- Supports grounding conductors above or below pathways, enables bonding to pathway sections and across pathway junctions when required
- Pre terminated on both ends
- Complies with all industry requirements to ensure a high level of safety and reliability
- Bonds the rack or cabinet to the (TGB)
Specifications
Specifications
Panduit - NKFP923LSSSM015 - Specifications
| Connector Type | Sc - Sc |
|---|---|
| Fiber Type | Os2 |
| Length | 15 M | 49.21 Ft. |
| Number Of Fibers | 2 Fiber |
| Type | Patch Cords |
| UNSPSC Code | 26121650 |
| Fiber Type | OS2 |
| Number of Fibers | 2 |
| Connector 1 Type | SC Duplex |
| Connector 2 Type | SC Duplex |
| Flammability Rating | LSZH |
| Maximum Connector Insertion Loss (dB) | 0.3 |
| Minimum Connector Return Loss (dB) | 50 |
| Overall Length (ft.) | 49.21 |
| Overall Length (m) | 14.99921 |
| Fiber Diameter (µm) | 9 |
| Outer Diameter (In.) | 0.118 |
| Outer Diameter (mm) | 3 |
| Maximum Operating Temperature (°C) | 60 |
| Maximum Operating Temperature (°F) | 140 |
| Minimum Operating Temperature (°C) | -10 |
| Minimum Operating Temperature (°F) | 14 |
| Resistance Properties | Flame-Resistant |
| Cable Color | Yellow |
| Standards Met | TIA/EIA 568-C.3-1 and ISO/IEC 61755-3-1 IEC-61754-7 (International), TIA-604-2-A, -3-A, and -10-A, FOCIS -2, -3, and -10, RoHS Complaint |
| Application | Provide interconnect and cross-connect of applications in entrance facilities, telecommunications rooms, data centers and at the desk. Support network applications to interconnect pre-terminated cassettes in main distribution, horizontal distribution and equipment distribution areas |
| Body Style | Duplex |
| Product Type | Fiber Optic Patch Cord |
| Sub Brand | NetKey |
| Part Features | Riser rated patch cords support installations that require this flame rating in specific environments |
| UPC | 07498392978 |
Panduit - NKFP923LSSSM015 - Environmental Information
| RoHS Status | ROHS3 Compliant |
|---|---|
| Moisture Sensitivity Level (MSL) | Not Applicable |
| ECCN | EAR99 |
| HTSUS | 8544.70.0000 |
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
