Panduit NKFP92ERLLSM020 | LC Patch Cord
-
Low prices.
Price match guarantee
-
In-House Experts.
We know our products
-
Easy Returns.
Quick & Hassle Free
-
Superior Selection.
Extensive product catalog
Description
Description
NetKey 2-fiber OS2 LC duplex to LC duplex patch cord, riser (OFNR) rated with 1.6mm jacket, 20m
NetKey fiber optic patch cords include duplex LC, SC and ST connectors on both ends and pigtails include simplex LC, SC and ST on one end and open (un-terminated) on the other end. Patch cords and pigtails meet requirements of TIA/EIA-568-C.3-1. The fiber connectors are FOCIS compliant or compatible and meet the requirements of TIA/EIA-455-21A. Quality control reference label provides lifetime traceability of test data.
Panduit NetKey Fiber Optic Patch Cord, 2 Fibers, 111.55 ft Length, LC Duplex to LC Duplex Connector, 9 um Core Dimension, 125 um Clad Dimension, OS2, Yellow
Panduit - NKFP92ERLLSM020 - Features
- Color specific keys with positive and negative keying features mechanically and visually distinguish connections to prevent unintentional insertion into unlike keyed or non-keyed ports, allow network design flexibility and versatility and accommodate more discrete networks
- Factory pre-polished fiber stub endface eliminates inconsistent and time consuming field polishing to deliver required optical performance
- Dual cam design with fiber and buffer clamps secures both the fiber and the buffer during the camming step to facilitate consistent termination results
- Allows up to two re-terminations to achieve optimum termination results, reduces the number of rejected connectors and terminations to provide yield rates approaching 100% for lower installed costs
- Translucent housing assembly facilitates inspection of the fiber termination quality, resulting in rapid installations, improved termination yields and lower installed costs
- Laser marked to identify fiber stub fiber type (9 um, 62.5, 50 or 50X)
- Non-optical disconnect design maintains data transmission under tensile loads for jacketed cable
- Universal termination tool with integrated visual termination indicator ensures fast, consistent and optimal terminations of all OptiCam connectors with connector specific cradles
- Spring loaded senior rear pivot latch LC connector
- Quick installation provide field termination in less than half the time of field polish connectors
- Patented re-termination capability provides yield rates approaching 100%
- Factory pre-polished fiber endface eliminates time consuming field polishing to reduce installation costs, labor, scrap and the number of tools required
- Cam activated fiber and buffer clamp mechanisms provide superior fiber and buffer retention less sensitivity to fiber tensile loading
- OptiCam termination tool simplifies tooling and termination and virtually eliminates operator error by providing visual indication of proper termination after the cam step has been completed
- Cable retention boot assemblies consistently provide higher than industry standard cable retention
- Insertion loss 0.3 dB average (multi-mode and single mode)
- Reduces the termination time compared to conventional termination methods
Specifications
Specifications
Panduit - NKFP92ERLLSM020 - Specifications
| Connector Type | Lc - Lc |
|---|---|
| Fiber Type | Os2 |
| Length | 20 M | 65.62 Ft. |
| Number Of Fibers | 2 Fiber |
| Type | Patch Cords |
| UNSPSC Code | 26121650 |
| Fiber Type | OS2 |
| Number of Fibers | 2 |
| Connector 1 Type | LC Duplex |
| Connector 2 Type | LC Duplex |
| Flammability Rating | Riser |
| Maximum Connector Insertion Loss (dB) | 0.3 |
| Minimum Connector Return Loss (dB) | 50 |
| Overall Length (ft.) | 65.61 |
| Overall Length (m) | 20 |
| Fiber Diameter (µm) | 9 |
| Outer Diameter (In.) | 0.06 |
| Outer Diameter (mm) | 1.6 |
| Maximum Operating Temperature (°C) | 60 |
| Maximum Operating Temperature (°F) | 140 |
| Minimum Operating Temperature (°C) | -10 |
| Minimum Operating Temperature (°F) | 14 |
| Resistance Properties | Flame-Resistant |
| Cable Color | Yellow |
| Standards Met | TIA/EIA 568-C.3-1 and ISO/IEC 61755-3-1 IEC-61754-7 (International), TIA-604-2-A, -3-A, and -10-A, FOCIS -2, -3, and -10, RoHS Complaint |
| Application | Provide interconnect and cross-connect of applications in entrance facilities, telecommunications rooms, data centers and at the desk. Support network applications to interconnect pre-terminated cassettes in main distribution, horizontal distribution and equipment distribution areas |
| Body Style | Duplex |
| Product Type | LC Patch Cord |
| Sub Brand | NetKey |
| Part Features | Riser rated patch cords support installations that require this flame rating in specific environments |
| UPC | 07498392735 |