3-phase monitored PDU with touchscreen LCD distributes and monitors power in a data center, server room or high-density network closet.
Features
- 14.5kW 3-Phase PDU Distributes and Monitors Network-Grade Power
- This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6H50BA features 30 C13 and 12 C19 200-240V outlets in three breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
- Built-In LX Platform Network Management Card Allows Remote Access 24/7
- The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
- Color Touchscreen LCD Offers Important Data at a Glance
- An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
- Easy to Install Vertically in an EIA-Standard 19 in. Rack
- The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A 6-ft. (1.83 m) cord with Hubbell CS8365C 200-240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.
- TAA-Compliant for GSA Schedule Purchases
- The PDU3EVN6H50BA is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Special Features
| High Availability PDU Features | Auto Probe Monitoring (included) |
|---|
Specifications
Specifications
Applications
- Power mission-critical rack equipment in a data center, computer room or high-density network closet in a government, commercial or industrial facility
- Monitor power loads from various computers, switches, servers and other networking equipment
Highlights
- 30 C13 and 12 C19 200-240V outlets distribute AC power to connected equipment
- Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management
- Installs in 0U of rack space in standard 19 in. racks using included mounting hardware
- 6-ft. (1.83 m) cord with Hubbell CS8365C 3-phase input connects to AC power source
- Color touchscreen LCD provides current levels, environmental data and network info
Overview
| UPC Code | 37332213556.0 |
|---|---|
| PDU Type | Monitored |
Input
| PDU Input Voltage | 200-240V |
|---|---|
| Recommended Electrical Service | Three-phase 50A 200-240V service |
| Maximum Input Amps | 35 |
| PDU Plug Type | HUBBELL CS8365C 50A |
| Input Phase | 3-Phase |
| Input Cord Length (ft.) | 6 |
Output
| Output Capacity Details | 14.5kW (240V), 13.9kW (230V), 13.3kW (220V), 12.6kW (208V), 12.1kW (200V) total capacity; 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet |
|---|---|
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacles | (30) C13; (12) C19 |
| Output Nominal Voltage | 200-240V |
| Overload Protection | 3 20A circuit breakers, 1 per outlet bank |
User Interface, Alerts & Controls
| Reported Load Segments | Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (20A balanced max per banks B1-B3); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 feeds black outlets (B1); L2-L3 feeds dark-gray outlets (B2); L3-L1 feeds light-gray outlets (B3) |
|---|---|
| Front Panel LCD Display | Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules; Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device) |
| Current Measurement Accuracy (Amps) | +/-1% |
| Voltage Measurement Accuracy (Volts) | +/-1% |
| Power Measurement Accuracy (Watts) | +/-1% |
Physical
| Form Factors Supported | Vertical rackmount installation supported with included mounting brackets; supports tooless mounting in button-mount compatible racks |
|---|---|
| Material of Construction | Metal |
Environmental
| Operating Temperature Range | 0C ~ 50C (32F ~ 122F) |
|---|---|
| Storage Temperature Range | -30°C to +60°C (-22°F to +140°F) |
| Relative Humidity | 5 to 95% non-condensing |
Communications
| SNMP Compatibility | Pre-installed LX platform network interface |
|---|
Standards & Compliance
| Certifications | Tested to UL60950-1: 2007 R10.14 (USA) CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011+A2: 2014 (Canada), NOM (Mexico), FCC Class A Part 15 (Emissions), ROHS, TAA Compliant |
|---|
Warranty
| Product Warranty Period (Worldwide) | 2-year limited warranty |
|---|
Documents and Downloads
Documents and Downloads
- User's Guide for WEBCARDLX PowerAlert Device Manager (English)
- Owner's Manual for 3-Phase Switched 0U Power Distribution Units (Multi-language)
- PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface User's Guide (English)
- PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface
- PowerAlert Device Manager (PADM) 20.0.0
- PDU3EVN6H50BA Submittal Drawing
- SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)
- PDU Buying Guide
- PADM20 High-Level Overview
- PowerAlert Device Manager v20
- PowerAlert Device Manager v20 for Networked Tripp Lite UPS Systems
- New Auto-Probe Feature on UPS Systems and PDUs
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.