Features
- Tripp Lite SMX3000XLRT2UA line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity and extended runtime options
- Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 158 to 278V
- C20 AC power inlet; 8 C13 and 1 C19 output receptacles, Two independently switchable output load banks
- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
- High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
- Internal batteries offer 11.1 minutes at 50% load (1350W) and 3.9 minutes at 100% load (2700W)
- Extended runtime is available with optional external battery packs BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible)
- External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
- Intelligent battery management system extends battery life
- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
- LCD interface also supports a number of advanced user setup and operating preferences
- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement
- Built-in USB, RS-232 and slot for optional network management card options
- Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD and RELAYIOCARD
- Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
- PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
- IP-based Auto Probe detects lost connectivity and restores service autonomously
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
- Built-in Emergency Power Off (EPO) interface with cable
Specifications
Specifications
Overview
| UPC Code | 37332181381 |
|---|---|
| UPS Type | Line-Interactive |
Input
| Rated input current (Maximum Load) | 14.1A |
|---|---|
| Nominal Input Voltage(s) Supported | 230V AC |
| UPS Input Connection Type | C20 inlet |
| UPS Input Connection Description | IEC320-C20 input connection accepts a variety of user supplied detachable C19 output cordsets to match country or site specific power sources |
| Input Circuit Breakers | 20A |
| Input Phase | Single-Phase |
Output
| Output Volt Amp Capacity (VA) | 3000 |
|---|---|
| Output kVA Capacity (kVA) | 3 |
| Output Watt Capacity (Watts) | 2700 |
| Output kW Capacity (kW) | 2.7 |
| Power Factor | 0,9 |
| Nominal Voltage Details | 230v nominal inverter output voltage |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Output Voltage Regulation (Line Mode) | +6%, -15% |
| Output Voltage Regulation (Battery Mode) | +/-5% |
Battery
| Battery Type | Valve Regulated Lead Acid (VRLA) |
|---|---|
| Full Load Runtime (min.) | 3.9 min. (2700w) |
| Half Load Runtime (min.) | 11.1 min. (1350w) |
| Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
| Expandable Runtime | Yes |
Voltage Regulation
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278 |
|---|---|
| Overvoltage Correction | Input voltages between 244 and 278 are reduced by 12% |
User Interface, Alerts & Controls
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
|---|---|
| Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Surge / Noise Suppression
| UPS AC Suppression Joule Rating | 350 |
|---|---|
| EMI / RFI AC Noise Suppression | Yes |
| AC Suppression Response Time | Instantaneous |
Communications
| Network Management Cards | SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; RELAYIOCARD |
|---|---|
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports; download PowerAlert Local software at https://www.tripplite.com/poweralert |
| Communications Cable | USB; DB9 and EPO cabling included |
| WatchDog Compatibility | Supports Watchdog application; OS and hard-reboot restart options for remote applications |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Documents and Downloads
Documents and Downloads
- SMX3000XLRT2UA runtime chart
- Owner's Manual for 230V 2U Rackmount UPS Systems (Multi-language)
- Quick Start Guide for PowerAlert Power Management Software
- Installation Guide for Select Rackmount UPS
- PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface User's Guide (English)
- Owner's Manual Addendum for External Battery Packs (Multi-Language)
- UPS 230V Brochure (English)
- Integrated Solutions Brochure (English)
- UPS Systems 230V Brochure (Chinese)
- EC Declaration
- UPS Systems Buying Guide
- Custom Products from Tripp Lite Are One Call Away
- Economy Mode Explained
- UPS Sizing
- Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
- PADM20 High-Level Overview
- PowerAlert Device Manager v20
- PowerAlert Device Manager v20 for Networked Tripp Lite UPS Systems
- New Auto-Probe Feature on UPS Systems and PDUs
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.